Page 45
Model 506 (UC Ice Maker)
Model 506 (UC Ice Maker)
Technical Data
7-3
#3752200 - Revision B - May, 2006
Water Solenoid Valve - .25 GPM Flow Washer - 80 Mesh Inlet Screen
Water Pump Motor - 39 Watts, .75 Amps, 3350 RPS
- Internal Overload
(Water distributor uses restricted inlet to obtain proper pump capacity)
Compressor Overload - Current and Ambient Sensitive
Compressor Relay - Current (magnetic) Type with N/O Start Contact
Condenser - Forced Air - Copper & Aluminum
Evaporator - Stainless Steel
Refrigerant Charge (R -134a) - See Serial Plate
Drier - Molecular Sleeve - High Side
Running Amps - 3.5 (average)
Bin Storage Capacity - 35 Lbs. Maximum
Ice Production Capacity - See Ice Production Chart Below
THERMOSTAT
CUT-IN
CUT- OUT
ALTITUDE CORRECTION
Ice Thickness (Evaporator)
Warm Position →
38°F " 1.5°F
38°F " 1.5°F
10.6 °F " 2.9°F
-4.8°F " 2.7°F
Bin Shut -off
41°F " 1.5°F
35°F " 1.5
IMPORTANT NOTE:
When changing an evaporator thermostat, make sure that at least 8" of capillary tube
is “S“ shaped and laying tight against the bracket soldered to the bottom of the evaporator. Tape at least 1"
of capillary tube to the hot gas line at the front edge of the evaporator. This shortens the defrost time.
Adjust range screw
according to chart on unit
thermostat bracket
ICE PRODUCTION (Lbs.) IN 24 HOURS
100°F
35
34
33
32
NOTE:
Maximum ice production will only be obtained under ideal
conditions. Production capacities shown in the above graph are
average and variances are normal.
Additional factors which reduce the production capacity are:
1
. Making cubes thicker than 1/2”.
2
. Increased ice meltage in storage bin due to high ambient
To maintain production capacity, avoid locating icemaker in
greasy or dusty atmosphere, or adjacent to high temperature
equipment such as ovens, ranges, steam tables, etc. . .
90°F
42
40
38
36
80°F
44
41
39
34
70°F
46
42
39
35
50°F
60°F
70°F
80°F
Water Temperature
Temperature (Fahrenheit)
Suction Pressure
at end of Freeze Cycle
Head pressure
at end of Freeze Cycle
Cycle Time in Minutes
Ambient 70 °/ Water 60 °
1 - 4
65 - 80
18 - 22
Ambient 90 °/ Water 60 °
2 - 5
85 - 100
21 - 27
Ambient 100 °/ Water 60 °
2 - 6
85 - 105
28 - 35
Ambient 70 °/ Water 80 °
1 - 4
65 - 80
20 - 25
Ambient 90 °/ Water 80 °
2 - 5
85 - 100
23 - 30
Ambient 100 °/ Water 80 °
2 - 6
85 - 105
30 - 38
PERFORMANCE DATE
A
m
b
ien
t Te
m
p
er
at
ur
e
Model 506 Undercounter Icemaker
(Starting with Serial # 1181341)
temperatures (25% is average).