Page 13
Model 506 (UC Ice Maker)
Model 506 (UC Ice Maker)
Installation & Maintenance
2-11
#3752200 - Revision B - May, 2006
Condenser Cleaning
It is necessary to periodically clean the air-cooled con-
denser to ensure efficient operation of the ice maker.
To clean the condenser:
1. Make sure the power is disrupted to the ice maker.
2. Remove the screws at the bottom of the grille and
remove grille and lower panel assembly.
3. Using a soft brush or a round dust brush attach-
ment to a vacuum cleaner, remove lint and dirt from
the condenser fins.
4. Use a vacuum cleaner to remove dirt from the bot-
tom of the unit compartment.
5. Replace the lower panel and grille assembly.
Reconnect the power supply.
Figure 2-19. Grille and Lower Panel Removal
Figure 2-20. Condenser Cleaning
TURN ICE MAKER OFF AND DISCONNECT FROM
THE MAIN POWER SUPPLY. CONDENSER FAN
ROTATION AND SHARP CONDENSER FINS COULD
RESULT IN PERSONAL INJURY.
DO NOT OPERATE ICE MAKER WITH LOWER
ACCESS PANEL OR CONTROL PANEL REMOVED.
DOING SO COULD RESULT IN DEATH, ELECTRI-
CAL SHOCK OR PERSONAL INJURY.
Screws