Min : MINIMUM Max : MAXIMUM
Fact. Set : FACTORY SETTING(DEFAULT)
Sr.
No.
Parameter setting method
Description of parameters and functions.
Parameter
To set other parameter
Press & hold SET key for
2 seconds
09
SP
To set the cut-out point of the controller.
Display will change to set value.
The set point value can now be changed
by using the UP/DOWN key.
01
To change Set Point parameter,
press the set key.
QFS+0.5
P2-0.5ºC
-20.0ºC
Range
Min
Max
Fact. Set
QFS
To set the quick freeze set point.
Use UP/DOWN keys to set desired value.
If controller is in quick freeze mode then
compressor will cut in/ cut out as per this
set point till the quick freeze duration is
over.
02
To change QFS parameter,
press the set key.
P3+0.5
SP-0.5
-25.0ºC
Range
Min
Max
Fact. Set
To set other parameter
Press & hold PRG key for
2 seconds
PRG
EXIT
End of set mode
03
10
Sr.
No.
Parameter setting method
Description of parameters and functions.
Parameter
01
P2
Parameter
Function :
To set allowable high
temperature limit.
To change P2 parameter,
press the set key.
Use UP/DOWN key to set desired value.
Once set at a particular value, this will not
allow the set point to go above this
value and below P3 setting.
Example :
Setting this parameter at
0
50.0 C will not allow the set point to go
0
above 50.0 C also if the temperature
0
reaches 50.0 C, the display will show HT
(High Temperature). The alarm will be
ON. But at power on till the ADT delay is
over controller will not generate HT Alarm.
SP+0.5ºC
50.0ºC
50.0ºC
Range
Min
Max
Fact. Set
(Message on Display)
(Message on Display)
02
P3
Parameter
Function :
To set allowable low
temperature limit.
Example
:
Setting this parameter at
Use UP/DOWN key to set desired value.
Once set at a particular value, this will not
allow the set point to go below this value
and above P2 setting.
0
-40.0 C will not allow the set point to go
0
below -40.0 C also if the temperature
0
reaches -40.0 C, the display will show LT
(Low Temperature). The alarm will be ON.
To change P3 parameter,
press the set key.
-40.0ºC
QFS-
0.5ºC
-40.0ºC
Range
Min
Max
Fact. Set
Example(Cooling Mode) :
If the set point
0
is set at 10.0 C and differential is set at
0
2.0 C, then when the system reaches
0
10.0 C, the comp. relay will cutout. Since
0
the differential is 2.0 C, the comp. Relay
0
will cutin at 12.0 C
0
0
(10.0 C + 2.0 C).
Use UP/DOWN keys to set desired value.
03
P4
Parameter
Function :
To set the differential for
compressor restart.
press the set key.
To change
P4
parameter,
0.5ºC
20.0ºC
2.0ºC
Range
Min
Max
Fact. Set
SET MODE
PROGRAM MODE
QFS = Quick Freeze Set Point
Display will show '0000'. Set correct
password to enter into program mode. The
display will show 'P2' and scroll the
description of the parameter.
To go to other parameters, use UP / DOWN
keys. After desired value, press the SET
key & you will see “----” which confirms that
the parameter value has been stored in
memory.
Display will show ‘SP’ and scroll the
description of the parameter.
To go to other parameters, use UP /
DOWN keys. After desired value, press
the SET key & you will see “----” which
confirms that the parameter value has
been stored in memory.
SP : Set Point.