Electronic Control System
Integrated
(700-
3
BASE)
Series
3-15
#3758424 - Revision B - December, 2005
Monitor and Control Refrigerator Fan-Assisted, Off-Cycle Defrost (700BR-3)
Temperature signals from refrigerator evaporator's thermistor’s are observed by the microprocessor. During off cycle
defrost, if a refrigerator zone temperature reaches high offset (calling for cooling) before evaporator temperature
rises to 38°F (3°C), no power will be supplied the the compressor. But, the the zone evaporator fan will switch ON.
Once the evaporator temperatur reaches 38°F (3°C), normal cooling functions begin. (See Figure 3-23).
NOTE:
If refrigerator compartment thermistor is faulty, compressor operation defaults to 20 minutes ON, 40 minutes
OFF cycling, EE appears in left of LCD, SERVICE will flash and Error Code 05 will be logged.
NOTE:
If evaporator thermistor is faulty, the compressor will not energize until zone air temperature exceeds high
offset by 5°F (3°C). SERVICE flashes and Error Code 06 is logged.
NOTE:
When in
Sabbath Mode, the
refrigerator compart-
ment thermistor still
controls compressor
operation, except
there is a random 15
to 25 second delay
before the compres-
sor is energized.
Figure 3-21. 700BR-3 Signal Trace - Regulate Refrigerator Zone
M
M
M
J3
P4
P3
P1
P2
UPPER DRAWER LIGHT
YELLOW
UPPER
LIGHT SWITCH
ORANGE W/BLACK STRIPE
LOWER
LIGHT SWITCH
ORANGE
PURPLE
BLACK
LOWER DRAWER LIGHT
STARTING
CONDENSER FAN
RELAY
REF FAN MOTOR
PROTECTOR
OVERLOAD
COMPRESSOR
COMPRESSOR
CAPACITOR
RUNNING
MAIN BOARD
PIN 1
PIN 1
PIN 1
PIN 1
PIN 1
WHITE
ORANGE
ORANGE W/BLACK STRIPE
ORANGE
(WHEN
USED)
RED
J5
J3
J4
J6
P2
J2
P1
P3
P4
60 CYCLES
L1
NEUTRAL
WHITE
WHITE
HIGH VOLTAGE SCHEMATIC
115 VOLTS
THERMISTOR EVAPORATOR
THERMISTOR UPPER DRAWER/REFRIGERATOR
DISPLAY BOARD
BLUE W/BLACK STRIPE
BLUE W/BLACK STRIPE
BLUE W/YELLOW STRIPE
ORANGE W/YELLOW STRIPE
MAIN BOARD
PIN 1
PIN 1
PIN 1
PIN 1
PIN 1
PIN 1
PIN 1
BLUE
ORANGE
WHITE
BLACK
YELLOW
RED
MEMBRANE KEYPAD
J5
J6
J4
J2
J3
J2
DISPLAY
LOW VOLTAGE SCHEMATIC
1. Thermistor at high off-set
temp. calling for cooling.
2. No Power
to lights.
5. compressor and
condenser fan
energized.
4. When Evap
Thermistor rises
above 38°F (3°C),
3. Evap fan energized.
Содержание 700-3 BASE
Страница 2: ......
Страница 12: ...Installation Information Integrated 700 3 BASE Series 2 4 3758424 Revision B December 2005 ...
Страница 40: ...Electronic Control System Integrated 700 3 BASE Series 3 28 3758424 Revision B December 2005 ...
Страница 48: ...Sealed System Information Integrated 700 3 BASE Series 4 8 3758424 Revision B December 2005 ...
Страница 52: ...Airflow Fan Blade Spacing Integrated 700 3 BASE Series 5 4 3758424 Revision B December 2005 ...
Страница 58: ...Icemaker Information Integrated 700 3 BASE Series 6 6 3758424 Revision B December 2005 ...
Страница 101: ...Technical Data Integrated 700 3 BASE Series 9 1 3758424 Revision B December 2005 SECTION 9 TECHNICAL DATA ...
Страница 114: ...Wire Diagrams Schematics Integrated 700 3 BASE Series 10 10 3758424 Revision B December 2005 ...