Electronic Control System
Integrated
(700-
3
BASE)
Series
3-7
#3758424 - Revision B - December, 2005
Icemaker System ON/OFF
All units with icemakers are shipped with the icemaker system switched OFF. By pressing the ICE ON/OFF key on
the control panel, power is allowed to the icemaker system, and “ICE” appears on the LCD (See Figure 3-9). To
disable the icemaker system, press the ICE ON/OFF key again and “ICE” will disappear from the LCD indicating the
icemaker system is OFF.
NOTE:
When unit is in “Sabbath Mode,” icemaker system is disabled. Sabbath Mode will be covered later.
NOTE:
To allow ice to freeze fully and reduce effects of low water pressure, power to the icemaker system is inter-
rupted for 45 minutes after each ice harvest. This can be bypassed for service purposes by pressing the ICE
ON/OFF key to switch the icemaker system OFF, then back ON.
Figure 3-9. Icemaker System ON/OFF - Press ICE ON/OFF Key
UNIT
ICE
REFRIGERATOR
ON/OFF
ON/OFF
ON/OFF
WARMER
COLDER
FREEZER
WARMER
COLDER
ICE
Ice system is active if “ICE” is displayed
Drawer Ajar Alarm ON/OFF
All units are equipped with a drawer ajar alarm feature. When activated, the alarm will alert a customer if a drawer
is stuck open or accidentally left open. To enable the drawer ajar alarm feature, press the drawer ajar alarm bell
ON/OFF key on the control panel. A bell icon will appear on the LCD indicating that the alarm feature is active.
(See Figure 3-10) Now, if a drawer is open for 30 seconds, the bell icon will blink and the audible alarm will beep.
To disable the drawer ajar alarm, simply press the drawer ajar alarm bell ON/OFF key and the bell icon on the LCD
will disappear, indicating the alarm feature is OFF.
Figure 3-10. Drawer Ajar Alarm ON/OFF - Press Alarm Bell ON/OFF Key
UNIT
ICE
REFRIGERATOR
ON/OFF
ON/OFF
ON/OFF
WARMER
COLDER
FREEZER
WARMER
COLDER
Alarm is active if bell is displayed
Содержание 700-3 BASE
Страница 2: ......
Страница 12: ...Installation Information Integrated 700 3 BASE Series 2 4 3758424 Revision B December 2005 ...
Страница 40: ...Electronic Control System Integrated 700 3 BASE Series 3 28 3758424 Revision B December 2005 ...
Страница 48: ...Sealed System Information Integrated 700 3 BASE Series 4 8 3758424 Revision B December 2005 ...
Страница 52: ...Airflow Fan Blade Spacing Integrated 700 3 BASE Series 5 4 3758424 Revision B December 2005 ...
Страница 58: ...Icemaker Information Integrated 700 3 BASE Series 6 6 3758424 Revision B December 2005 ...
Страница 101: ...Technical Data Integrated 700 3 BASE Series 9 1 3758424 Revision B December 2005 SECTION 9 TECHNICAL DATA ...
Страница 114: ...Wire Diagrams Schematics Integrated 700 3 BASE Series 10 10 3758424 Revision B December 2005 ...