Regulate Freezer Zone Temperature (700BCI-3, 700BFI-3)
When the thermistor in the freezer compartment reaches high off-set temperature, calling for cooling, the compres-
sor and condenser fan are energized, but the evaporator fan is not allowed to run until the thermistor on the evapo-
rator reaches 35°F (2°C). (See Figure 3-19)
If either drawer is opened while the evaporator fan is operating, the microprocessor will detect the power signal to
the lights and cut power to the fan.
Though compartment air temperatures will fluctuate, LCD displays average temperature.
NOTE:
If compartment temperature exceeds either high or low offset (Ex: drawer is left open), temperature display
will change by one
degree per minute.
NOTE:
If freezer
compartment thermis-
tor is faulty, compres-
sor operation defaults
to 20 minutes ON, 20
minutes OFF cycling,
EE appears in left of
LCD, SERVICE will
flash and Error Code
07 will be logged.
NOTE:
If evaporator
thermistor is faulty,
the compressor will
be energized after
the dwell time and
the evaporator fan
will be energized 3
minutes later. SER-
VICE will flash and
Error Code 08 will be
logged.
NOTE:
When in
Sabbath Mode, the
freezer compartment
thermistor still con-
trols compressor
operation, except
there is a random 15
to 25 second delay
before the compres-
sor is energized.
Figure 3-19. 700BCI-3 Signal Trace - Regulate Freezer Zone
REF (TOP)
DRAWER LIGHT
YELLOW
REF LIGHT
SWITCH
ORANGE W/BLACK STRIPE
FRZ LIGHT
SWITCH
ORANGE
RED
PURPLE
60 CYCLES
BLACK
L1
NEUTRAL
WHITE
FRZ (BOTTOM)
DRAWER LIGHT
STARTING
FRZ FAN MOTOR
CONDENSER FAN
RELAY
PROTECTOR
OVERLOAD
COMPRESSOR
COMPRESSOR
CAPACITOR
RUNNING
WHITE
HIGH VOLTAGE SCHEMATIC
115 VOLTS
THERMISTOR LOWER
DRAWER/FREEZER
THERMISTOR
EVAPORATOR
DISPLAY BOARD
LOW VOLTAGE SCHEMATIC
BLUE W/BLACK STRIPE
BLUE W/BLACK STRIPE
BLUE W/RED STRIPE
ORANGE W/RED STRIPE
MAIN BOARD
PIN 1
PIN 1
PIN 1
PIN 1
PIN 1
PIN 1
PIN 1
MAIN BOARD
PIN 1
PIN 1
PIN 1
PIN 1
PIN 1
MEMBRANE KEYPAD
WHITE
ORANGE
ORANGE W/BLACK STRIPE
ORANGE
(WHEN
USED)
J3
J5
P4
P3
P1
P2
J6
J4
J2
J3
J2
DISPLAY
J5
J3
J4
J6
P2
J2
P1
P3
P4
M
M
M
M
1. Thermistor at high off-set
temp. calling for cooling.
2. No signal
to lights.
3. Compressor and
condenser fan
energized.
4. Evap Thermistor
below 35°F (2°C).
5. Evap fan
energized.
Содержание 700-3 BASE
Страница 2: ......
Страница 12: ...Installation Information Integrated 700 3 BASE Series 2 4 3758424 Revision B December 2005 ...
Страница 40: ...Electronic Control System Integrated 700 3 BASE Series 3 28 3758424 Revision B December 2005 ...
Страница 48: ...Sealed System Information Integrated 700 3 BASE Series 4 8 3758424 Revision B December 2005 ...
Страница 52: ...Airflow Fan Blade Spacing Integrated 700 3 BASE Series 5 4 3758424 Revision B December 2005 ...
Страница 58: ...Icemaker Information Integrated 700 3 BASE Series 6 6 3758424 Revision B December 2005 ...
Страница 101: ...Technical Data Integrated 700 3 BASE Series 9 1 3758424 Revision B December 2005 SECTION 9 TECHNICAL DATA ...
Страница 114: ...Wire Diagrams Schematics Integrated 700 3 BASE Series 10 10 3758424 Revision B December 2005 ...