WARNING

                 

INTRODUCTION

Thank you for using our flood projector CityColor.

The CityColor projects, thanks to an extremely efficient optic system (international patent n. WO99/40361), a powerful light beam which 
can create numberless color shades. Its performances, in terms of luminousity and lighted surfaces, can reach incredible levels.

The CityColor IP54 comes in the following versions:

• Art. 0002     CITYCOLOR IP54 1800W 
• Art. 0003     CITYCOLOR IP54 2500W High Power

The CityColor can work in automatic mode or in synchro mode, otherwise may be controlled by 8 bit DMX controllers

The input protocol is the DMX 512. To drive the CityColor we suggest to use either our controller DMX Control Spot, the
Control Show 512 the Easy Control or the Fancy.

To make  the most  of its possibilites and for a correct  functioning of this unit in the years to come, we suggest you to read carefully 
this manual before connecting or putting the spot into use. By doing so you will gain experience with its commands and connections 
and you will be easily able to use it.

WARNING

!

SAFETY INFORMATION

READ ALL CAUTIONS AND WARNINGS PRIOR TO OPERATE THIS EQUIPMENT.

INSTRUCTION TO PREVENT INJURY OR DAMAGE DUE TO ELECTRIC SHOCK, FIRE, MECHANICAL HAZARDS AND 

UV RADIATION HAZARDS.

• PROTECTION AGAINTS FIRE

1) IMPORTANT: Use only the lamps showed on page n. 3. 
    

DO NOT USE ANY OTHER TYPE LAMP!

2) Maintain minimum distance of 0.5 meter from walls or any other type flammable surfaces.
3) Maintain minimum distance to lighted objects of 5.0 meter.
4) Replace fuses only with the specified type and rating.
5) Do not install the spot close to heat sources. Do not lay the connection cable on the spot when it is warm.

• PROTECTION AGAINST ELECTRIC SHOCK

1) This equipment must be earthed.
2) Class I equipment. The power supply cord includes a protective earthing conductor as part of the cord.
3) For connection to the supply mains proceed as pict.1 page 3. The equipment must be connected to branch circuit having a
    circuit- breacker In=16A Id=0.03A (230VAC) (art.0002) or In=32A Id=0.03A (230VAC) (art.0003)
4) Disconnect power before lamp’s replacement or servicing (service personnel).

• PROTECTION AGAINST MECHANICAL HAZARDS

1) Use secondary safety chain when fixing this equipment.
2) Hot lamp explosion hazard. Do not open the equipment for 300 seconds after switching off.
3) Equipment surface may reach temperature up to 100°C. Allow about five minutes before handling.
4) Replace the lamp if it is damaged or thermally deformed.

• PROTECTION AGAINST UV RADIATION HAZARDS

1) Do not start on this equipment without lamp enclosure or if the protection screens, or ultraviolets screens are damaged.
2) The protection screens, the lenses, or the ultraviolet filters must be replaced if they are visibly damaged and their effectiveness
    has been reduced, for example, by cracks or deep scratches.
3) Do not look directly at the lamp while lamp is on.

Check that the spot has not been damaged during transport. If it has been damaged or it does not work, address  

the  seller. Whether the spot has been shipped to you directly, please contact the shipping company.

Only the consignee (person or company) can claim for these damages.

!

Содержание CITYCOLOR 2500 IP54

Страница 1: ...amming functions page 8 Use of the CityColor in DMX 512 page 9 DMX signal connection page 10 DMX line and termination page 11 Automode functioning page 12 Troubleshooting page 13 System board connecti...

Страница 2: ...o lighted objects of 5 0 meter 4 Replace fuses only with the specified type and rating 5 Do not install the spot close to heat sources Do not lay the connection cable on the spot when it is warm PROTE...

Страница 3: ...in real time BEAM ANGLE 50 intensity 50 x52 CONTROL INPUT Standard interface RS 485 opto couplet input Protocol USITT DMX 512 SETUP AND CONFIGURATION On the control panel with menu and buttons AUTOMO...

Страница 4: ...in pict 1 For connection to the mains supply proceed as pict 1 The equipment must be connected to branch circuit having a circuit breacker In 16A Id 0 03A 230VAC art 0002 or In 32A Id 0 03A 230VAC art...

Страница 5: ...h fingers If this happenes clean the bulb before use with dry cloth and alcohol 7 Put down the two upper lampholders D 8 Connect the cables E to the two ends of the lamp or connect the two cables of t...

Страница 6: ...t use the filters in critical working conditions and normally when the fixture works outdoor You must remove the filters when the ambient temperature is over 35 C You must regularly clean the filters...

Страница 7: ...flashing the lamp switching off is remotely controlled off lamp switched on DIMMER led flashing the lamp is 33 dimmered off lamp switched on BUTTONS Four buttons are used to programme the spot MENU t...

Страница 8: ...e that the selected option is different from the pre set one The available options are no normal for the functioning in DMX reception Pr01 Pr15 pre set 01 15 for the master functioning with the re spe...

Страница 9: ...A page 26 7 CHANNELS 6 CHANNELS CH 1 Motor speed CH 1 Motor speed CH 2 Cyan CH 2 Cyan CH 3 Yellow CH 3 Yellow CH 4 Magenta CH 4 Magenta CH 5 Dimmer CH 5 Dimmer CH 6 Basic colors rainbow CH 6 Basic co...

Страница 10: ...mly suggested to use a cable for high speed data transmission sect 2x0 25 gnd If the lines have a total length over 150 200 mts it is suggested to use a signal amplifier art 3004 DMX repeter amplifier...

Страница 11: ...nctioning of the DMX line The terminator is a resistor fitted between the two data lines pins 2 and 3 of an XLR 5 pin connector at the end of the cable furthest from the transmitter The terminator res...

Страница 12: ...g it flashes to indicate that the selected option is different from the pre set one The available options are no normal for the functioning in DMX reception Pr01 Pr27 pre set 01 27 for the master func...

Страница 13: ...s before accessing the lamp after operation 4 Disconnect the unit from power before removing any cover Q T If the procedures do not solve your problem and you need to call for assistance please provid...

Страница 14: ...14 DATA LINK 512 DMX TOUBLESHOOTING Appendix C Table A2 14...

Страница 15: ...MOT2 DIMMER MOT5 CYAN U12 7805 5V TO HEAD THERMAL SENSOR AND SWITCH MAIN POWER INPUT TO CC250 TO PCB CC250 MOT4 YELLOW U5 U6 U7 U8 U9 L6219 MOTOR DRIVER U10 MICRO PWM FAN CONTROLLER MOT3 MAGENTA TO L...

Страница 16: ...N IP connector if the led is on check PCB PAN IP 2 Check U13 78M05 L3 D6 If the led 5V is off 1 Disconnect TO DISPLAY PCB PAN IP connector if the led is on check PCB PAN IP 2 Check D4 L2 U12 If the le...

Отзывы: