![STUDIO DUE CITYCOLOR 2500 IP54 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/studio-due/citycolor-2500-ip54/citycolor-2500-ip54_manual_1386750010.webp)
10
pict.5
pict.5a
CONNECTION THE DATA LINK (DMX 512)
The connection of the DMX signal to the CITYCOLOR must be made by using the signal input XLR 5 pin connectors which are located
on the control panel of the fixture. (pict.5)
The pin nomenclature of the connectors for the connection to the DMX signal is listed in the table. (pict.5a)
In order to avoid any problem in the signal transmission, it is warmly suggested to use a cable for high speed data transmission
(sect. > 2x0.25 + gnd).
If the lines have a total length over 150-200 mts it is suggested to use a signal amplifier (art. 3004 - DMX repeter amplifier).
The usage of a normal microphonic or audio cable is suggested only for lines max 100 mts long.
To ensure the IP54 rate you must connect the DMX cable inside the base. Use the given cables fixing (pict. 5b) and connect by
following the cables numbering (pict. 5c).
fig.5c
fig.5b
PIN
WIRE
SIGNAL
1
SHIELD
GROUND/RETURN/OV
2
INNER CONDUCTOR
DATA COMPLEMENT (-, INVERTED)
3
INNER CONDUCTOR
DATA TRUE (+, NON INVERTED)