STUDIO DUE CITYCOLOR 2500 IP54 Скачать руководство пользователя страница 1

Safety informations ........................................................................................................................... page 2

Technical features.............................................................................................................................. page 3

Before using....................................................................................................................................... page 4

Lamp  installation, replacement and setting .................................................................................... page 5

Installation of the dust proof filters .................................................................................................. page 6

Control panel  and configuration...................................................................................................... page 7

Programming functions .................................................................................................................... page 8

Use of the CityColor in DMX 512 ..................................................................................................... page 9

DMX signal connection..................................................................................................................... page 10

DMX line and termination ................................................................................................................ page 11

Automode functioning ...................................................................................................................... page 12

Troubleshooting ............................................................................................................................... page 13

System board connection ................................................................................................................ page 15

Electric diagrams     .......................................................................................................................... page 17

Components and parts...................................................................................................................... page 22

Technical drawings............................................................................................................................ page 23

Appendix A (DMX values) ................................................................................................................ page 26

Appendix B (games).......................................................................................................................... page 27

rev. 4/02.05

INTERNATIONAL PATENT WO99/40361

IP•54

ENGLISH INDEX

Содержание CITYCOLOR 2500 IP54

Страница 1: ...amming functions page 8 Use of the CityColor in DMX 512 page 9 DMX signal connection page 10 DMX line and termination page 11 Automode functioning page 12 Troubleshooting page 13 System board connecti...

Страница 2: ...o lighted objects of 5 0 meter 4 Replace fuses only with the specified type and rating 5 Do not install the spot close to heat sources Do not lay the connection cable on the spot when it is warm PROTE...

Страница 3: ...in real time BEAM ANGLE 50 intensity 50 x52 CONTROL INPUT Standard interface RS 485 opto couplet input Protocol USITT DMX 512 SETUP AND CONFIGURATION On the control panel with menu and buttons AUTOMO...

Страница 4: ...in pict 1 For connection to the mains supply proceed as pict 1 The equipment must be connected to branch circuit having a circuit breacker In 16A Id 0 03A 230VAC art 0002 or In 32A Id 0 03A 230VAC art...

Страница 5: ...h fingers If this happenes clean the bulb before use with dry cloth and alcohol 7 Put down the two upper lampholders D 8 Connect the cables E to the two ends of the lamp or connect the two cables of t...

Страница 6: ...t use the filters in critical working conditions and normally when the fixture works outdoor You must remove the filters when the ambient temperature is over 35 C You must regularly clean the filters...

Страница 7: ...flashing the lamp switching off is remotely controlled off lamp switched on DIMMER led flashing the lamp is 33 dimmered off lamp switched on BUTTONS Four buttons are used to programme the spot MENU t...

Страница 8: ...e that the selected option is different from the pre set one The available options are no normal for the functioning in DMX reception Pr01 Pr15 pre set 01 15 for the master functioning with the re spe...

Страница 9: ...A page 26 7 CHANNELS 6 CHANNELS CH 1 Motor speed CH 1 Motor speed CH 2 Cyan CH 2 Cyan CH 3 Yellow CH 3 Yellow CH 4 Magenta CH 4 Magenta CH 5 Dimmer CH 5 Dimmer CH 6 Basic colors rainbow CH 6 Basic co...

Страница 10: ...mly suggested to use a cable for high speed data transmission sect 2x0 25 gnd If the lines have a total length over 150 200 mts it is suggested to use a signal amplifier art 3004 DMX repeter amplifier...

Страница 11: ...nctioning of the DMX line The terminator is a resistor fitted between the two data lines pins 2 and 3 of an XLR 5 pin connector at the end of the cable furthest from the transmitter The terminator res...

Страница 12: ...g it flashes to indicate that the selected option is different from the pre set one The available options are no normal for the functioning in DMX reception Pr01 Pr27 pre set 01 27 for the master func...

Страница 13: ...s before accessing the lamp after operation 4 Disconnect the unit from power before removing any cover Q T If the procedures do not solve your problem and you need to call for assistance please provid...

Страница 14: ...14 DATA LINK 512 DMX TOUBLESHOOTING Appendix C Table A2 14...

Страница 15: ...MOT2 DIMMER MOT5 CYAN U12 7805 5V TO HEAD THERMAL SENSOR AND SWITCH MAIN POWER INPUT TO CC250 TO PCB CC250 MOT4 YELLOW U5 U6 U7 U8 U9 L6219 MOTOR DRIVER U10 MICRO PWM FAN CONTROLLER MOT3 MAGENTA TO L...

Страница 16: ...N IP connector if the led is on check PCB PAN IP 2 Check U13 78M05 L3 D6 If the led 5V is off 1 Disconnect TO DISPLAY PCB PAN IP connector if the led is on check PCB PAN IP 2 Check D4 L2 U12 If the le...