background image

LED states

LAN gateway LEDs

LED 

name

LED 

colour

State

Indication

Ready

Red

Always On Power is on and the NPort is booting up.
Blinking

Indicates an IP conflict, or DHCP or BOOTP server is not responding properly.

Green

Always On Power is on and the NPort is functioning normally.
Blinking

The NPort has been located by the NPort Administrator’s Location function.

-

Off

Power is off, or a power error.

Link

Orange

Always On 10 Mbps Ethernet connection.

Green

Always On 100 Mbps Ethernet connection.

-

Off

Ethernet cable is disconnected.

Tx/Rx

Orange

Always On

Serial port is receiving data.

Green

Always On Serial port is transmitting data.

-

Off

No data is being transmitted or received through the serial port.

Xcom-232i LED

LED 

colour

State

Indication

Red

Blinks

(Ton = 50 % | Toff = 50 %)

Updating process.

 During the Xcom-232i updating process (after inser

-

tion of a MicroSD card containing the updates), the signalisation LED 

blinks in red with a cyclical ratio of 50 %.

Always on

Error during update or back up of the data logger.

  If the Xcom-232i 

detects an error, the signalisation LED is continuously red.

Blinks 

(Ton = 10 % | Toff = 90 %)

MicroSD card full.

 If the Xcom-232i detects that the MicroSD card is full, 

the signalisation LED blinks in red with a cyclical ratio of 10 % .

Green

Always on

Data logging. 

When the data logging function is activated, the signalisa

-

tion LED is green.

Blinks continuously

(Ton = 20 % | Toff = 80 %)

Communication (via RS-232 connection).

 When the communication 

via the RS-232 connection is active, the signalisation LED blinks in green 

with a cyclical ratio of 20 %.

Blinks 2x

In operation. 

The signalisation LED blinks in green twice when the Xcom-

232i is in operation and none of the above mentioned states is indicated.

Orange

On 1.5s

Insertion of the SD card. 

When inserting an SD card, the signalisation 

LED is both red and green simultaneously for 1.5 second.

If several of the three states indicated by the red LED light occur simultaneously, they will be displayed in 

the following priority order:

• 

Update processing

• 

Error during updating

• 

MicroSD card full

If the two states indicated by the green LED light occur simultaneously, the signal indicating communication 

via RS-232 connection is reversed (Ton=80% |Toff=20%).

 

Содержание Xcom-LAN

Страница 1: ...Remote communication set for Xtender systems Xcom LAN Quickguide Copyright Studer Innotec SA V 1 2 1 4O9E7 ...

Страница 2: ...ance between the Xcom 232i and the Studer system should not exceed 10 meters The distance between the Xcom 232i and the Ethernet gateway should not exceed 0 25 m All cables you need are provided in the set ATTENTION The metallic casing of the Ethernet gateway is connected to the negative battery pole Therefore it is necessary to isolate its casing from any metallic surface Wiring Set the terminati...

Страница 3: ...here is no message the Xcom is not connected to the server Use the FAQ of this Quick guide to see what could have gone wrong 10 11 i n T T Run the Xcom configurator 8 Choose LAN as Xcom mode No other parameters are re quired The gateway is already configured Press Generate to save the parameter settings A window will automatically confirm the successful file generation Take note of your GUID file ...

Страница 4: ...c support in order to replace your set Xcom portal I can t register my new installation What should I do To register a new installation the installa tion needs to be 1 Configured correctly and in accord ance with the user manual 2 Have been connected to the server at least once In order to validate that the installation has been correctly configured the Xcom sys tem info available on the RCC conne...

Страница 5: ...a logger If the Xcom 232i detects an error the signalisation LED is continuously red Blinks Ton 10 Toff 90 MicroSD card full If the Xcom 232i detects that the MicroSD card is full the signalisation LED blinks in red with a cyclical ratio of 10 Green Always on Data logging When the data logging function is activated the signalisa tion LED is green Blinks continuously Ton 20 Toff 80 Communication vi...

Страница 6: ... one year starting from the date of purchase The updates are no longer guaranteed beyond this date and a hardware upgrade may be required Please contact your reseller for any additional information on compatibility SAFETY PRECAUTIONS Generalities Carefully read all safety instructions before pro ceeding with the installation and commissioning of the device Failure to follow these instructions migh...

Отзывы: