background image

Studer Innotec SA 

Xcom-485i 

4   

V1.0.0 

User manual

 

1.3.2

 

Disclaimer of liability 

Installation,  commissioning,  use  and  maintenance  of  this  device  cannot  be  supervised  by  the 
company Studer Innotec SA. For this reason, we do not accept any liability for damages, costs or 
losses generated either by an installation that is not conforming to the prescriptions, by a defective 
operation or by poor maintenance. The use of this device is under the responsibility of the end-user. 
This device is neither designed nor guaranteed for the supply of life support applications or any 
other  critical  application  with  potential  risks  for  human  beings  or  for  the  environment.  We  shall 
assume no liability for patent infringement or other third-party rights involved in the use of this device. 

1.3.3

 

Compatibility 

Studer Innotec SA guarantees the compatibility of the software updates with the hardware for one 
year, starting from the date of purchase. The updates are no longer guaranteed beyond this date 
and  a  hardware  upgrade  may  be  required.  Please  contact  your  reseller  for  any  additional 
information on compatibility. 

1.4

 

S

AFETY PRECAUTIONS

 

1.4.1

 

Generalities 

Carefully read all safety instructions before proceeding with the installation and commissioning of 
the device. Failure to follow these instructions might constitute a lethal physical danger but can 
also damage the functionalities of the device. Therefore, this manual should always be kept close 
to the device. 

 

1.4.2

 

Warnings 

 

Wherever the system is, the person in charge of installation and commissioning must know 
the  safety  measures  and  the  prescriptions  in  force  in  the  country.  Therefore,  the  whole 
maintenance must be carried out by qualified personnel. 

 

All components connected to this device must be conforming to the laws and regulations 
in force. Persons without a written authorization from Studer Innotec SA are forbidden to do 
any changes, modifications or repairs whatsoever. Regarding authorized modifications and 
replacements, only genuine components shall be used. 

 

This device is meant for indoor use only and must under no circumstances be exposed to 
rain, snow or any other humid or dusty environment. 
 

1.5

 

P

RODUCT RECYCLING

 

The Xcom-485i meets the European RoHS directive 2011/65/EU on 
hazardous  substances  and  does  not  contain  the  following 
elements: lead, cadmium, mercury, hexavalent chromium, PBB 
or PBDE. 
To dispose of this product, please use the service for collection of 
electrical waste and observe all obligations in force in the place 
of purchase. 

 

 

 

For any installation, the local and national norms and regulations in force must be 
strictly followed. 

Содержание Xcom-485i

Страница 1: ...Studer Innotec SA 2019 V1 0 0 4O9T Xcom 485i Isolated RS 485 communication module for Xtender and Vario systems User Manual ...

Страница 2: ...i communication set 6 3 2 Other required material 6 4 FUNCTIONALITIES OF THE XCOM 485I 7 5 INSTALLATION OF THE XCOM 485I 7 5 1 Selection of functionality and pinout arrangement 7 5 2 Cable between Xcom 485i and third party device 8 5 3 Selection of the PIN assignment of the RS 485 bus connection 8 5 4 Mounting 8 5 5 Connection of the communication bus Studer side 10 5 6 Connection of third party d...

Страница 3: ...ll respect of fixed procedures Each Xcom 485i is given a serial number allowing a perfect follow up of the controls in conformity with the specific data of every device For this reason it is very important to never remove the descriptive sticker with the serial number The production assembly and tests of each Xcom 485i are entirely carried out in our factory in Sion CH The warranty of this product...

Страница 4: ...th the installation and commissioning of the device Failure to follow these instructions might constitute a lethal physical danger but can also damage the functionalities of the device Therefore this manual should always be kept close to the device 1 4 2 Warnings Wherever the system is the person in charge of installation and commissioning must know the safety measures and the prescriptions in for...

Страница 5: ...lowing EU directives and standards Low Voltage Directive LVD 2014 35 EU EN 62368 1 2014 AC 2015 Electromagnetic Compliance EMC Directive 2014 30 EU EN 61000 6 1 2007 EN 61000 6 2 2005 AC 2005 EN 61000 6 4 2007 A1 2011 2 1 CONTACT INFORMATION Studer Innotec SA Rue des Casernes CH 1950 Sion Switzerland 41 0 27 205 60 80 41 0 27 205 60 88 info studer innotec com www studer innotec com ...

Страница 6: ...y system SCADA PLC etc you will need a specific cable crafted with the proper connector and pinning on each side See chapter 5 2 One Xcom 485i module Two 2 meters communication cables to connect the Xcom 485i to Studer and external devices Mounting plate 2 DIN rail clips and screws SD card with manual This device should not be used for any purpose not described in this manual The device is using R...

Страница 7: ...umid or dusty environment As far as possible reduce exposure to sudden temperature variation important heat variation may create undesired and harmful condensation inside the equipment Before installing the module the configuration of the function and the selection of pin out connection must be achieved 5 1 SELECTION OF FUNCTIONALITY AND PINOUT ARRANGEMENT To access the DIP switches and jumper arr...

Страница 8: ...ctor which can be connected to any signal of the communication interface GND D D using the jumpers By default no connexion is done inside the module so you have to open it and configure it manually The EIA TIA 485 standard uses A A and B B signal names for data signals However this naming is subject to interpretation as most of the IC manufacturers uses it in a wrong way In order to avoid this con...

Страница 9: ...Studer Innotec SA Xcom 485i User manual V1 0 0 9 ...

Страница 10: ...opriate connector recommended by the third party device SCADA PLC etc and on the other side an RJ 45 connector Do not connect the Xcom 485i between devices connected to the battery Do not connect the module to a device not connected to the battery RCC or other Xcom The termination switch of the communication bus Com Bus remains in position T terminated except when both connectors are used In this ...

Страница 11: ...ide of the device Do not connect any devices suited for standard Ethernet connection d Switch for communication line ending This switch activates or deactivates the communication bus termination The termination is by default activated terminated In Figure 3 the termination is activated Place the switch to the correct side if there is only one cable connected on port c com bus put the switch in T t...

Страница 12: ...A PLC etc on RS 485 Do not connect any devices suited for standard Ethernet connection f Switch for RS 485 termination This switch activates or deactivates the communication bus termination The termination is by default activated In Figure 4 the termination is activated T Place the switch to the correct side if there is only one cable connected on port e put the switch in T terminated position If ...

Страница 13: ...e micro SD card The micro SD card must not be removed until the end of the updating process If for some reason the updating process is interrupted reinsert the SD card to let the process finish The latest software versions are available on our website www studer innotec com en downloads under the heading Softwares and Updates The updating process can take between 3 and 15 minutes During this perio...

Страница 14: ...Studer Innotec SA Xcom 485i 14 V1 0 0 User manual 7 DIMENSIONS ...

Страница 15: ...Studer Innotec SA Rue des Casernes 57 1950 Sion Switzerland Tel 41 0 27 205 60 80 Fax 41 0 27 205 60 88 info studer innotec com www studer innotec com ...

Отзывы: