Studer Innotec SA

 

 Xcom-485i 

User manual

 

V1.0.0 

3

 

1

 

INTRODUCTION 

This manual contains a complete description of Xcom-485i communication module. This device is 
a bridge between the proprietary Studer communication bus on one side and RS-485 (isolated) on 
the  other  side.  The  protocol  used  on  the  RS-485  side  is  Modbus  RTU  (see  our  website  for  more 
information). 

1.1

 

L

EGAL NOTICE

 

The use of Studer Innotec SA devices is the responsibility of the customer in all cases. Studer Innotec 
SA reserves the right to make any modification to the product without prior notice. 

1.2

 

C

ONVENTIONS

 

1.2.1

 

Symbols 

 

This symbol indicates a risk of material damage. 

 

This symbol indicates a procedure or function that is important for a safe and correct 
use  of  the  equipment.  Failure  to  respect  these  instructions  may  lead  to  the 
cancellation of the guarantee or to a non-compliant installation. 

1.3

 

W

ARRANTY AND LIABILITY

 

During production and assembly, each Xcom-485i undergoes several controls and tests. These are 
carried out in full respect of fixed procedures. Each Xcom-485i is given a serial number allowing a 
perfect  follow-up  of  the  controls,  in  conformity  with  the  specific  data  of  every  device.  For  this 
reason,  it  is  very  important  to  never  remove  the  descriptive  sticker  with  the  serial  number.  The 
production, assembly and tests of each Xcom-485i are entirely carried  out in our factory in Sion 
(CH). The warranty of this product depends on the strict following of the instructions in this manual. 
The warranty period for the Xcom-485i is 5 years as from the date of delivery ex-works. 

1.3.1

 

Exclusion of warranty 

No warranty will be applied for damages caused by handling, operation or actions that are not 
described  in  this  manual.  Damages  arisen  from  the  following  events  are  not  covered  by  the 
warranty: 

 

Overvoltage on the device. 

 

Liquid in the device or oxidation due to condensation. 

 

Failures due to a fall or to a mechanical shock. 

 

Modifications made without the explicit authorization of Studer Innotec SA. 

 

Nuts or screws partially or insufficiently tightened during installation or maintenance. 

 

Damages due to atmospheric overvoltage (lightning). 

 

Damages due to transport or improper packaging. 

 

Disappearance of original marking items. 

 

 

Содержание Xcom-485i

Страница 1: ...Studer Innotec SA 2019 V1 0 0 4O9T Xcom 485i Isolated RS 485 communication module for Xtender and Vario systems User Manual ...

Страница 2: ...i communication set 6 3 2 Other required material 6 4 FUNCTIONALITIES OF THE XCOM 485I 7 5 INSTALLATION OF THE XCOM 485I 7 5 1 Selection of functionality and pinout arrangement 7 5 2 Cable between Xcom 485i and third party device 8 5 3 Selection of the PIN assignment of the RS 485 bus connection 8 5 4 Mounting 8 5 5 Connection of the communication bus Studer side 10 5 6 Connection of third party d...

Страница 3: ...ll respect of fixed procedures Each Xcom 485i is given a serial number allowing a perfect follow up of the controls in conformity with the specific data of every device For this reason it is very important to never remove the descriptive sticker with the serial number The production assembly and tests of each Xcom 485i are entirely carried out in our factory in Sion CH The warranty of this product...

Страница 4: ...th the installation and commissioning of the device Failure to follow these instructions might constitute a lethal physical danger but can also damage the functionalities of the device Therefore this manual should always be kept close to the device 1 4 2 Warnings Wherever the system is the person in charge of installation and commissioning must know the safety measures and the prescriptions in for...

Страница 5: ...lowing EU directives and standards Low Voltage Directive LVD 2014 35 EU EN 62368 1 2014 AC 2015 Electromagnetic Compliance EMC Directive 2014 30 EU EN 61000 6 1 2007 EN 61000 6 2 2005 AC 2005 EN 61000 6 4 2007 A1 2011 2 1 CONTACT INFORMATION Studer Innotec SA Rue des Casernes CH 1950 Sion Switzerland 41 0 27 205 60 80 41 0 27 205 60 88 info studer innotec com www studer innotec com ...

Страница 6: ...y system SCADA PLC etc you will need a specific cable crafted with the proper connector and pinning on each side See chapter 5 2 One Xcom 485i module Two 2 meters communication cables to connect the Xcom 485i to Studer and external devices Mounting plate 2 DIN rail clips and screws SD card with manual This device should not be used for any purpose not described in this manual The device is using R...

Страница 7: ...umid or dusty environment As far as possible reduce exposure to sudden temperature variation important heat variation may create undesired and harmful condensation inside the equipment Before installing the module the configuration of the function and the selection of pin out connection must be achieved 5 1 SELECTION OF FUNCTIONALITY AND PINOUT ARRANGEMENT To access the DIP switches and jumper arr...

Страница 8: ...ctor which can be connected to any signal of the communication interface GND D D using the jumpers By default no connexion is done inside the module so you have to open it and configure it manually The EIA TIA 485 standard uses A A and B B signal names for data signals However this naming is subject to interpretation as most of the IC manufacturers uses it in a wrong way In order to avoid this con...

Страница 9: ...Studer Innotec SA Xcom 485i User manual V1 0 0 9 ...

Страница 10: ...opriate connector recommended by the third party device SCADA PLC etc and on the other side an RJ 45 connector Do not connect the Xcom 485i between devices connected to the battery Do not connect the module to a device not connected to the battery RCC or other Xcom The termination switch of the communication bus Com Bus remains in position T terminated except when both connectors are used In this ...

Страница 11: ...ide of the device Do not connect any devices suited for standard Ethernet connection d Switch for communication line ending This switch activates or deactivates the communication bus termination The termination is by default activated terminated In Figure 3 the termination is activated Place the switch to the correct side if there is only one cable connected on port c com bus put the switch in T t...

Страница 12: ...A PLC etc on RS 485 Do not connect any devices suited for standard Ethernet connection f Switch for RS 485 termination This switch activates or deactivates the communication bus termination The termination is by default activated In Figure 4 the termination is activated T Place the switch to the correct side if there is only one cable connected on port e put the switch in T terminated position If ...

Страница 13: ...e micro SD card The micro SD card must not be removed until the end of the updating process If for some reason the updating process is interrupted reinsert the SD card to let the process finish The latest software versions are available on our website www studer innotec com en downloads under the heading Softwares and Updates The updating process can take between 3 and 15 minutes During this perio...

Страница 14: ...Studer Innotec SA Xcom 485i 14 V1 0 0 User manual 7 DIMENSIONS ...

Страница 15: ...Studer Innotec SA Rue des Casernes 57 1950 Sion Switzerland Tel 41 0 27 205 60 80 Fax 41 0 27 205 60 88 info studer innotec com www studer innotec com ...

Отзывы: