background image

General safety instructions

2.2.2

Obligations of the operating company

Safety-conscious working

Operate the pump only if it is in perfect technical condition
and use it only as intended, staying aware of safety and
risks, and in adherence to the instructions in this manual.

Ensure that the following safety aspects are observed and
monitored:

Intended use

Statutory or other safety and accident-prevention reg-
ulations

Safety regulations governing the handling of haz-
ardous substances

Applicable standards and guidelines in the country
where the pump is operated

Applicable guidelines of the operator

Make personal protective equipment available.

Qualified personnel

Make sure all personnel tasked with work on the pump
have read and understood this manual and all other appli-
cable documents, especially the safety, maintenance and
repair information, before they start any work.

Organize responsibilities, areas of competence and the
supervision of personnel.

Ensure that all work is carried out by specialist technicians
only:

Installation, repair and maintenance work

Transportation

Work on the electrical system

Make sure that trainee personnel only work on the pump
under supervision of specialist technicians.

Safety equipment

Provide the following safety equipment and verify its func-
tionality:

For hot, cold and moving parts: pump safety guarding
provided by the customer

For pumps without capability to run dry: Dry run pro-
tection

For potential electrostatic charging: provide suitable
grounding

Warranty

Obtain the manufacturer's approval prior to carrying out
any modifications, repairs or alterations during the warranty
period.

Only use genuine parts or parts that have been approved
by the manufacturer.

2.2.3

Obligations of personnel

All directions given on the pump must be followed (and kept
legible), e.g. the arrow indicating the sense of rotation and
the markings for fluid connections.

Pump, coupling guard and components:

Do not step on them or use as a climbing aid

Do not use them to support boards, ramps or beams

Do not use them as a fixing point for winches or sup-
ports

Do not use them for storing paper or similar materials

Do not use the hot pump or motor components as a
heating point

Do not de-ice the pump using gas burners or similar
tools

Do not remove the safety guarding for hot, cold or moving
parts during operation.

Use personal protective equipment if necessary.

Only carry out work on the pump while it is not running.

Before all installation and maintenance work, disconnect
the motor from the mains and secure it against being
switched back on again.

Never reach into the suction or discharge flange.

Following all work on the pump, refit safety devices in
accordance with the instructions and bring into service.

Do not make any modifications to the device.

300 092

BA-2018.08.21 EN

SHM

7

Содержание SHM 20-15

Страница 1: ...ion BA 2018 08 21 EN Print No 300 092 TR MA DE Rev004 ST BBE GmbH Co KG Hollwieser Stra e 5 32602 Vlotho Germany Phone 49 0 5733 799 0 Fax 49 0 5733 799 5000 E mail contact stuebbe com Internet www st...

Страница 2: ...s 17 5 4 1 Keeping the piping clean 17 5 4 2 Installing suction pipe 17 5 4 3 Installing the pressure pipe 17 5 4 4 Inspection for stress free pipe connections 17 5 5 Electrical connection 17 5 5 1 Co...

Страница 3: ...3 Measures to be taken if the pump is shut down 19 Tab 4 Measures depending on the behavior of the pumped liquid 19 Tab 5 Fault number assignment 26 Tab 6 Troubleshooting list 28 Tab 7 Designation of...

Страница 4: ...ollow this manual and the other applicable documents especially all safety instructions and warnings 1 2 Other applicable documents Document purpose Where found ATEX additional manual 300 365 Addition...

Страница 5: ...azardous situation Minor injury Potentially hazardous situation Material damage Safety warning sign Take note of all information highlighted by the safety warning sign and follow the instructions to a...

Страница 6: ...flow and speed data sheet The power consumption of the pump increases as the spe cific gravity of the pumped fluid increases Adhere to the permissible specific gravity in order to eliminate the pos si...

Страница 7: ...cold and moving parts pump safety guarding provided by the customer For pumps without capability to run dry Dry run pro tection For potential electrostatic charging provide suitable grounding Warranty...

Страница 8: ...itional manual Additional instructions for use in explosive atmospheres www stuebbe com pdf_manuals 300365 pdf 2 3 3 Magnetic field The magnetic field of the magnetic coupling can destroy prod ucts th...

Страница 9: ...7 Fig 1 Name plate example 1 Pump type 2 Serial number 3 Ident number 4 Housing sealing material 5 Shaft seal information 6 Impeller diameter mm 7 Differential head 8 Flow 3 1 2 ATEX type plate Typ Se...

Страница 10: ...Layout and Function 3 2 Description Non self priming horizontal centrifugal pump Magnetically coupled and hermetically sealed 10 SHM BA 2018 08 21 EN 300 092...

Страница 11: ...n flange 2 Pressure flange 3 Magnetic coupling 4 Terminal box 5 Motor 6 Base frame 7 Volute casing 3 4 Shaft seals Only one of the following shaft seals is used 3 4 1 Magnetic coupling Magnetic coupli...

Страница 12: ...cking and inspection on delivery 1 Unpack the pump pump assembly upon delivery and inspect it for transport damage 2 Check completeness and accuracy of delivery 3 Ensure that the information on the na...

Страница 13: ...pump properly 1 Seal all openings with blind flanges blind plugs or plastic covers 2 Make sure the storage room meets the following condi tions Dry Frost free Vibration free UV protected 3 Rotate the...

Страница 14: ...ns 9 2 1 Ambient conditions Page 32 5 1 2 Preparing the installation site Ensure the installation site meets the following conditions Pump is freely accessible from all sides Sufficient space for the...

Страница 15: ...1 Fill the anchoring holes with mortar casting compound 2 When the mortar casting compound has set bolt the base plate at three points to the specified tightening torque 3 Before tightening the remai...

Страница 16: ...y and control devices recommended Avoid contamination 1 Install filters in the suction pipe 2 Install a differential pressure gauge with contact manome ter to monitor contamination Avoid reverse runni...

Страница 17: ...cooled down 1 Disconnect the pipe connecting flanges from the pump 2 Check whether the pipes can be moved freely in all direc tions within the expected range of expansion Nominal width 150 mm by hand...

Страница 18: ...on Page 17 6 2 Commissioning 6 2 1 Switching on Pump set up and connected properly Motor set up and connected properly Align motor precisely to the pump All connections stress free and sealed All safe...

Страница 19: ...back on again WARNING Risk of injury and poisoning due to hazardous pumped liquids Use protective equipment for any work on the pump Collect leaking liquid safely and damage fitting in accor dance wi...

Страница 20: ...stomer seals O rings shaft sealing rings 6 5 Operating the stand by pump Stand by pump filled and bled Operate the stand by pump at least once a week 1 Fully open the suction side fitting 2 Open press...

Страница 21: ...itions reduce the service life of antifriction bearings Plain bearings are subject to natural wear and tear which is heavily dependent on the respective operating condi tions It is therefore not possi...

Страница 22: ...keep a safe distance of 1 m Make sure that no magnetizable metal parts can be attracted by the pump s magnetic coupling Make sure that parts of the magnetic coupling cannot be attracted by the magneti...

Страница 23: ...ce Pressure gauge lines pressure gauge and fixtures dis mounted WARNING Risk of injury during disassembly work on the magnetic coupling Use jacking screws to disassemble the bearing bracket in order t...

Страница 24: ...e casing 102 1 11 Remove the impeller 230 1 from the shaft 210 1 12 Remove thrust bearing 314 3 from the volute casing 13 Remove thrust bearing 314 4 from the impeller 14 Remove thrust bearing 314 5 f...

Страница 25: ...motor coupling mechanical seal blocking pressure sys tem cardan shaft drives belt drive etc WARNING Risk of injury during assembly work on the magnetic cou pling Use jacking screws to assemble the be...

Страница 26: ...ossible faults are identified by a fault number in the table below This number identifies the respective cause and rem edy in the troubleshooting list Fault Number Pump not pumping 1 Pumping rate insu...

Страница 27: ...e pipe Install a larger impeller and consult the manufacturer X X X Pressure side fitting not opened wide enough Open the pressure side fitting X X X Magnetic coupling has parted Switch off pump and s...

Страница 28: ...impeller X X X Hydraulic parts of the pump dirty clotted or encrusted Dismount the pump Clean the parts X X Plain bearing faulty Replace plain bearing X Defective antifriction bearing in motor Replac...

Страница 29: ...ring 412 5 Sealing ring 505 1 Reinforcement ring 545 1 Bearing bush 554 1 Washer 554 2 Washer 554 3 Washer 580 1 Protection cap 580 2 Protection cap 580 3 Protection cap 801 1 Motor 817 1 Rear cover 8...

Страница 30: ...ix 9 1 2 Drawing SHM 20 15 855 1 904 1 314 5 545 1 412 5 210 1 545 1 230 1 314 3 102 1 817 1 554 2 901 2 934 1 554 1 901 1 580 1 801 1 341 1 Fig 7 Replacement parts SHM 20 15 30 SHM BA 2018 08 21 EN 3...

Страница 31: ...314 5 412 5 210 1 545 1 230 1 314 3 102 1 901 1 554 1 934 1 723 4 314 4 505 1 891 1 801 1 904 1 412 2 723 3 723 1 412 1 341 1 901 3 934 3 554 3 901 2 554 2 723 2 580 3 580 1 580 2 Fig 8 Replacement pa...

Страница 32: ...ling ring up to max 10 bar Profile sealing ring up to max 16 bar O ring max 16 bar 16 10 5 5 5 20 15 10 10 10 25 20 12 12 12 32 25 15 12 12 40 32 20 15 15 50 40 25 15 15 63 50 30 20 20 75 65 35 20 20...

Страница 33: ...70 73 70 73 Tab 14 Maximum sound pressure level sizes SHM50 40S SHM50 40L and SHM65 50 Measuring conditions Distance to the pump 1 m Operation free of cavitation Motor IEC standard motor Tolerance 3...

Страница 34: ...k discharge pressure Operating temperatures Weekly Check motor temperature Undoable screwed connections quarterly Check for correct and tight fitting Impeller Plain bearing Bearing bushes O rings As r...

Страница 35: ...s ET ETL ETLB ETLB S ETLB T ETLB ST to which this declaration relates are in conformity with the following standards Machinery Directive 2006 42 EC EMC Directive 2014 30 EU With regard to electrical h...

Отзывы: