background image

- 2 -

Cont ...

PRODUCT DESCRIPTION

The Shower Waste Pump Kit is an automatic drainage system, for removal of water from 
showers, wet rooms and level access bathrooms.

Please note the following warning signs.

Warning of possible electrical hazard.

Possible danger to personnel or important installation requirement.

APPLICATION

 

All the safety and operating instructions in this booklet must be  

 

 followed. 

 

The unit must not be used for any other application without the  

 

 

written consent of Stuart Turner Limited.

 

The unit must be installed by a qualified person.

 

The unit is not suitable for heavy commercial/industrial  

 

 

 applications.

 

The plumbing installation must comply with the latest Building  

 

 Regulations.

 

The wiring installation must comply with the latest Wiring   

 

 Regulations 

(BS7671).

 

This appliance can be used by children aged from 8 years and  

 

 

above and persons with reduced physical, sensory or mental  

 

 

capabilities or lack of experience and knowledge if they have  

 

 

been given supervision or instruction concerning use of the  

 

 

appliance in a safe way and understand the hazards involved.   

 

 

Children shall not play with the appliance.  Cleaning and user  

 

 

maintenance shall not be made by children without supervision.

 

Children should be supervised to ensure that they do not play with  

 the 

appliance.

Please read installation details carefully as they are intended to ensure this 
product provides long, trouble free service.  Failure to install the unit in 
accordance with the installation instructions will lead to invalidation of the 
warranty.

STORAGE

If this product is not to be installed immediately on receipt, ensure that it is stored in a dry, 
frost and vibration free location in its original packaging.

Содержание Wasteflo

Страница 1: ...er with Tiled Floor Gully SWP TF Part No 46597 Shower Waste Pump Controller with Sheet Vinyl Floor Gully SWP SF Part No 46598 Shower Waste Pump Controller with 90 mm Shower Tray Gully SWP 90 Part No 4...

Страница 2: ...t Wiring Regulations BS7671 This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if t...

Страница 3: ...ightly from the picture above Item Description Qty Item Description Qty Controller 1 Pump 1 Controller bracket 4 Housing 1 Fixing screw 4 M4 washer 2 Mounting washer 3 M4 screw 2 Cable grommet 1 Joker...

Страница 4: ...nce instructions provided with the gully These parts are not supplied Cable to connect pump to controller HO5VV F2 2 5 mm2 IP55 cable connector suitable for 2 5 mm2 cable Screws and raw plugs to mount...

Страница 5: ...sembly must be located away from the direct line of water jets where possible 1 13 Both the controller and pump must be positioned away from heat sources such as radiators and heaters Care must be tak...

Страница 6: ...controller A using the screws C provided Fig 1 Now fix the controller to the wall using suitable fixing screws 3 18 Step 3 Pump installation First fix 3 off adhesive mounting washers D to the back of...

Страница 7: ...disconnection must be incorporated in the fixed wiring 4 17 A suitable method of connection would be via a double pole switched fused connection unit complying with BS 1363 4 protected with a fuse see...

Страница 8: ...our PumpAssist Helpline As water is heated scale deposits are released in areas of hard water It is recommended that a non acid based descalent is used to remove limescale To be carried out every thre...

Страница 9: ...Ensure the Sensor Switch Float is free to move up down on the Shaft 5 If the Sensor Switch Float is stuck not freely moving clean any detriment from the Shaft ensuring no damage to the Shaft or Float...

Страница 10: ...o C Connections Pump connections 22 mm OD compression fitting Pump Duty rating 30 mins on 30 mins off Electrical Power supply phase frequency 230 V a c 1 50 Hz Current full load 0 3 Amps Power consum...

Страница 11: ...ical specification section Check circuit breaker is set Thermal protection activated Wait approximately 20 minutes for the circuit to reset Gully float switch stuck Clean gully to ensure float operate...

Страница 12: ...ied that the product has been purchased within the guarantee term prior to the date of claim such as proof of purchase or the shower waste pump serial number This guarantee is in addition to your stat...

Страница 13: ...co uk and complete a short form which will enable visitors to find your contact details on our web site installer finder Alternatively use your smartphone to scan this QR code and go straight to the f...

Страница 14: ...14 NOTES...

Страница 15: ...15 NOTES...

Страница 16: ...PUMP AS SERIAL NUMBER BELOW COMPLIES WITH THE ESSENTIAL REQUIREMENTS OF THE ABOVE E E C DIRECTIVES RESPONSIBLE PERSON AND MANUFACTURER STUART TURNER LIMITED HENLEY ON THAMES OXFORDSHIRE RG9 2AD ENGLA...

Страница 17: ...se the Sensor Switch Float within the Gully to stick and prevent the pump system from operating see Routine Maintenance section Acid based descalents and aggressive cleaning agents must not be used to...

Страница 18: ...secured by the 4 x M6 Stainless Steel Screws and insert the Temporary Cover Plate into Gully 9 Test drainage system for air and water tightness 10 Concrete Floors make good around the Gully ensuring...

Страница 19: ...e Clamp Ring but not solvent welded at this stage 10 Concrete Floors make good around the Gully ensuring that the Gully Body is fully supported DO NOT rely solely on support under the Gully Flange 11...

Страница 20: ...ensure no damage occurs Fig 13 Flush with clean water 4 Ensure the Sensor Switch Float is free to move up down on the Shaft 5 If the Sensor Switch Float is stuck not freely moving clean any detriment...

Отзывы: