The pump must never run dry, needing a minimum water depth of 90 mm on the

Supersub model and 100 mm on the Supervort models, at all times.

Adjustment of the float switch is achieved by lengthening or shortening the cable

through the moulded cable retention slot, which is located in the pump handle (Figs 6 and
7).

Note:  When inserting cable into slot ensure it is fully engaged.

If modification of the level setting is required refer to Figures 8 and 9 and the following

chart.

Use of a Stuart non-return valve, Part No 26702 is recommended on the discharge side

to limit back flow and pump surging when draining small areas.

If the pump is required to drain, for instance, a cellar, then it must be installed in a

sump, having sufficient dimensions for the float switch to operate freely (Fig. 10), retaining
a minimum water depth as previously stated.  The pump is continuously rated when fully
submerged but should only be run for short periods (10 mins) when the water drops to the
minimum level.  The number of starts should not exceed 30 per hour.

Note:  It is not possible to empty the sump completely, a minimum depth must remain

(Figs. 8 & 9).

Fig. 8 Min. Float
Switch Movement

Fig. 9 Max. Float
Switch Movement

Fig. 10 Min. Size Of Sump

Chart shows min. and max. float switch adjustment

Pump handle

Moulded
cable
retention slot

Float switch
cable shown
slotted into
position

Fig. 6

Fig. 7

A

B

C

D

E

F

PUMP TYPE

START

(MIN.ADJ)

STOP

(MIN.ADJ)

CABLE

(MIN.ADJ)

START

(MAX.ADJ)

STOP

(MAX.ADJ)

CABLE

(MAX.ADJ)

SUB 460A

VORT 550A

VORT 560A

400

410

440

200

190

230

220

220

220

480

460

490

90

100

100

350

320

330

Содержание Supersub 460A

Страница 1: ...Submersible Pumps OPERATING INSTRUCTIONS Please leave this instruction booklet with the pump as it contains maintenance and safety information...

Страница 2: ...PLICATION This pump set must not be used for any other application without the written consent of Stuart Turner Limited and in particular must not be connected directly to the mains water supply or us...

Страница 3: ...ble pump with float switch control on selected models Motor All motors are induction type permanent capacitor fitted with integral auto resetting thermal overload protection IP68 enclosure class B ins...

Страница 4: ...Amps Enc Rating Duty Rating Dims mm Gross Weight packed kg No of Pump Stages L W H Supersub 460A 230 1 50 730 510 3 3 IP68 Continuous 155 140 325 7 2 1 Supervort 550A 230 1 50 320 225 1 4 IP68 Contin...

Страница 5: ...pped hose connector and a non return valve which should be screwed into the pump outlet port Fig 6 Fig 2 Supersub Fig 3 Supervort Fig 4 Diver Fig 5 Diver Outlet Hose Connector Non Return Valve Outlet...

Страница 6: ...pumps should be positioned away from pond plants if applicable to maximise flow and prevent entanglement Diver When siting these pumps in a location where organic or general debris is likely ensure t...

Страница 7: ...ance a cellar then it must be installed in a sump having sufficient dimensions for the float switch to operate freely Fig 10 retaining a minimum water depth as previously stated The pump is continuous...

Страница 8: ...ALLATION WARNINGS The electrical installation must be carried out in accordance with the current national electrical regulations and installed by a competent person A residual current device having a...

Страница 9: ...ug incorporating a fuse the value of which is indicated on the pin face of the plug Should the fuse need to be replaced an ASTA approved BS 1362 fuse must be used of the same rating marked thus If the...

Страница 10: ...ire which is coloured brown must be connected to the terminal marked with the letter L or coloured red Fuses The following fuse size should be used with the appropriate pump Supply Cord Replacement Th...

Страница 11: ...e fully submerged before starting Take care when submerging the pump to ensure all air is purged from the casing This is done by slowly submerging the pump and gently agitating whilst doing so This wi...

Страница 12: ...pipe Fig 11 4 Refer to commissioning section for instructions on re starting pump Supervort Range 1 Disconnect electrical supply before working on pump 2 Release system pressure from pipework and remo...

Страница 13: ...o not use cable to lift pump 3 Clean inlet filter grille using water pressure from a hose pipe 4 Refer to commissioning section for instructions on re starting pump STORAGE If this product is not inst...

Страница 14: ...tall and connect cable Pump will not start Power not connected to the electricity supply Impeller jammed Float switch not working if fitted Check the cable is connected correctly and power supply is s...

Страница 15: ...VIRONMENT PROTECTION Your appliance contains valuable materials which can be recovered or recycled At the end of the products useful life please leave it at an appropriate local civic waste collection...

Страница 16: ...e telephone Stuart Turner Ltd on 01491 572655 or return pump with accessories removed Proof of purchase should accompany the returned unit to avoid delay in action DECLARATION OF CONFORMITY 2006 95 EC...

Отзывы: