Stuart Turner Supersub 460A Скачать руководство пользователя страница 3

- 3 -

General

The submersible pump range is designed for re-circulation, drainage and transfer of

fresh water in outdoor or indoor applications.

Model types within the range which have the suffix ‘A’ incorporate an adjustable float

switch assembly which provides automatic pump control.

An optional foam pre-filter is available for the Supersub model - contact Stuart Turner

Ltd for further details.

Supersub Range

This model is suitable for clean water, rain water or waste water applications.
Note: Waste water is water that has been used in the home except water from toilets 

eg. dish, shower and laundry water.

Supervort Range

These models are suitable for dirty water applications and are capable of handling

semi-solids in suspension of up to 20 mm in diameter.  They are also suitable for all
applications specified in the Supersub range.

Diver range

This model range has high head (pressure) capabilities and is suitable for clean water

applications only.

PRODUCT DESCRIPTION

Electric motor driven submersible pump with float switch control on selected models.

Motor

All motors are induction type, permanent capacitor, fitted with integral auto-resetting

thermal overload protection, IP68 enclosure, class ‘B’ insulation and continuously rated.

The motor is encapsulated in a casing and protected from water ingress by three

separate lip seals running on a shaft sleeve, lubricated with a biodegradable vegetable oil.

Pump

All models are close coupled to the motor and are of centrifugal design and are

supplied as standard with a stepped hose connector.

Both Supersub and Supervort are single stage units and are supplied pre-fitted with a

10 metre mains supply cord.

Diver 3 and 4 are three and four stage units respectively and are supplied as standard

with a non-return valve and are pre-fitted with a 15 metre mains supply cord.

Standard pump materials of construction of major wetted parts are as follows.

Model

Body

Impeller

Shaft

Motor
Encapsulent

Shaft
Sleeve

Seal
(Lip)

Supersub

Polypropylene

Noryl

Stainless Steel

Stainless Steel

Ceramic

Nitrile

Supervort

Polypropylene

Noryl

Stainless Steel

Stainless Steel

Ceramic

Nitrile

Diver

Polypropylene

Noryl

Stainless Steel

Stainless Steel

Ceramic

Nitrile

Cont....

Содержание Supersub 460A

Страница 1: ...Submersible Pumps OPERATING INSTRUCTIONS Please leave this instruction booklet with the pump as it contains maintenance and safety information...

Страница 2: ...PLICATION This pump set must not be used for any other application without the written consent of Stuart Turner Limited and in particular must not be connected directly to the mains water supply or us...

Страница 3: ...ble pump with float switch control on selected models Motor All motors are induction type permanent capacitor fitted with integral auto resetting thermal overload protection IP68 enclosure class B ins...

Страница 4: ...Amps Enc Rating Duty Rating Dims mm Gross Weight packed kg No of Pump Stages L W H Supersub 460A 230 1 50 730 510 3 3 IP68 Continuous 155 140 325 7 2 1 Supervort 550A 230 1 50 320 225 1 4 IP68 Contin...

Страница 5: ...pped hose connector and a non return valve which should be screwed into the pump outlet port Fig 6 Fig 2 Supersub Fig 3 Supervort Fig 4 Diver Fig 5 Diver Outlet Hose Connector Non Return Valve Outlet...

Страница 6: ...pumps should be positioned away from pond plants if applicable to maximise flow and prevent entanglement Diver When siting these pumps in a location where organic or general debris is likely ensure t...

Страница 7: ...ance a cellar then it must be installed in a sump having sufficient dimensions for the float switch to operate freely Fig 10 retaining a minimum water depth as previously stated The pump is continuous...

Страница 8: ...ALLATION WARNINGS The electrical installation must be carried out in accordance with the current national electrical regulations and installed by a competent person A residual current device having a...

Страница 9: ...ug incorporating a fuse the value of which is indicated on the pin face of the plug Should the fuse need to be replaced an ASTA approved BS 1362 fuse must be used of the same rating marked thus If the...

Страница 10: ...ire which is coloured brown must be connected to the terminal marked with the letter L or coloured red Fuses The following fuse size should be used with the appropriate pump Supply Cord Replacement Th...

Страница 11: ...e fully submerged before starting Take care when submerging the pump to ensure all air is purged from the casing This is done by slowly submerging the pump and gently agitating whilst doing so This wi...

Страница 12: ...pipe Fig 11 4 Refer to commissioning section for instructions on re starting pump Supervort Range 1 Disconnect electrical supply before working on pump 2 Release system pressure from pipework and remo...

Страница 13: ...o not use cable to lift pump 3 Clean inlet filter grille using water pressure from a hose pipe 4 Refer to commissioning section for instructions on re starting pump STORAGE If this product is not inst...

Страница 14: ...tall and connect cable Pump will not start Power not connected to the electricity supply Impeller jammed Float switch not working if fitted Check the cable is connected correctly and power supply is s...

Страница 15: ...VIRONMENT PROTECTION Your appliance contains valuable materials which can be recovered or recycled At the end of the products useful life please leave it at an appropriate local civic waste collection...

Страница 16: ...e telephone Stuart Turner Ltd on 01491 572655 or return pump with accessories removed Proof of purchase should accompany the returned unit to avoid delay in action DECLARATION OF CONFORMITY 2006 95 EC...

Отзывы: