- 6 -
SITING OF THE PUMP
WARNINGS:
Do not run against a closed valve for periods longer than 5 minutes.
The water in and around the pump must not be allowed to freeze. This
will result in pump damage.
Do not under any circumstances use the supply cord fitted, as a
means to carry or lower the pump into position on installation. Attach
a rope sling to handle.
Do not allow plastic pump parts to come into contact with solder flux,
oil or cellulose based paints, paint thinners or strippers, acid based
descalents or aggressive cleaning agents.
Never run pump whilst sucking air/water as the motor will overheat.
To prevent this happening always install pump in the vertical position
and ensure fully submerged.
When siting the pump ensure its base is raised slightly from the
bottom of the sump reducing the possibility of blocking the filter with
debris or drawing in small stones.
General
The pump must be installed in the vertical position and must be fully submerged at all
times to avoid overheating of the motor. Float switch controlled pumps may be operated
partially submerged for short periods (see float switch operation section for further details).
The pumps should be positioned away from pond plants (if applicable) to maximise flow
and prevent entanglement.
Diver
When siting these pumps in a location where organic or general debris is likely, ensure
the base is raised slightly from the bottom of the sump (eg. on a flat paving slab) to
prevent the integral inlet filter grille being frequently blocked with debris.
If the pump is not to sit on the bottom of the sump, or it is too deep, then it should be
suspended by a rope attached to the lifting eye or handle located on top of the pump.
Supersub
When siting this pump in a location where organic or general debris is likely, ensure the
pump is placed on its base on a flat horizontal surface (eg. on a paving slab) to enable
full functionality of the primary inlet filter grille, which in turn will prevent the secondary
inlet filter grille from being frequently blocked.
Supervort
When siting these pumps in a location where organic or general debris is likely, ensure
the base is raised slightly from the bottom of the sump (eg. on a flat paving slab) to
prevent the force of the pump from drawing in small stones.
This will result in pump
damage.
Float Switch Operation
Selected models which include the suffix ‘A’ after the model number, are fitted with float
switches for automatic operation.
The following guide will help you get the most out of your pump.