- 10 -
Wiring (Diver range)
The Wires in the mains lead (supply cord) are coloured in accordance with the following
code:
Green and Yellow: Earth
Blue: Neutral
Brown: Live
As colours of the core in the new mains lead may not correspond with the coloured
markings identifying the terminals in your connection unit, proceed as follows:
The wire which is coloured green and yellow must be connected to the terminal marked
with the letter 'E' or by the earth symbol
or coloured green or green and yellow.
The wire which is coloured blue must be connected to the terminal marked with the
letter 'N' or coloured black.
The wire which is coloured brown must be connected to the terminal marked with the
letter 'L' or coloured red.
Fuses
The following fuse size should be used with the appropriate pump.
Supply Cord Replacement
The power supply cord of this pump cannot be replaced. If the cord is damaged, the
pump should be scrapped.
Float Switch Cord Replacement
The float switch cord cannot be replaced. If the cord is damaged the pump should be
scrapped.
Supply Cord Extension (Pump)
The pumps are fitted with a supply cord suitable for outdoor and underwater use. The
cord specification is as follows:-
Model
Fuse Size (Amps)
All Models
13
Pump Type
Cord Type
Cord Length (m)
Supersub 460A
HO5RN-F3 G 0.75 mm²
10
Supervort 550A
HO5RN-F3 G 0.75 mm²
10
Supervort 560A
HO7RN-F3 G 1 mm²
10
Diver 3
HO7RN-F3 G 1 mm²
15
Diver 4
HO7RN-F3 G 1 mm²
15