-13 -
Diver Range
1)
Disconnect electrical supply before working on pump.
2)
Release system pressure from pipework and remove pump from water (do not use
cable to lift pump).
3)
Clean inlet filter grille using water pressure from a hose pipe.
4)
Refer to commissioning section for instructions on re-starting pump.
STORAGE
If this product is not installed immediately on receipt, store in a frost and vibration free
location in its original packaging.
Cover
Inlet Filter
Grille
Fig. 17 Diver