Installation Instructions
For Monsoon Universal
Twin Pump
Medium Pressure U1.5 bar
High Pressure U3.0 bar
Medium Pressure U2.0 bar
High Pressure U4.0 bar
High Pressure U4.5 bar
PRODUCT DESCRIPTION
Electric motor driven twin ended peripheral pumps complete with an automatic control
system, consisting of flow switches, pressure switch and pressure vessel and electronic
controls.
APPLICATION
Monsoon Universal pumps are suitable for positive or negative head installation
conditions. The pumps are designed for whole house pressure boosting applications in
vented stored water systems. Inlet pressures to the pump and ambient temperatures
must not exceed the values given in the technical specifications.
This pump set must not be used for any other application without the
written consent of Stuart Turner Limited and in particular, must not be
connected directly to the mains water supply.
This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible
for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
WARNING - Washer/condenser dryers and condenser dryers.
The pump must not be used in the water supply line to a washer/
condenser drier or a condenser drier, which uses a constant flow of
cold water to aid the condenser drying process, as damage can occur
to the pump. If in doubt or for further information contact Stuart
Turner Ltd.
Please leave this instruction booklet with the pump as it contains
maintenance and safety information (Original Instructions)
INDEX
. . . . . . . . . . . . . . . . . . . . . . . .Page No
Product Description . . . . . . . . . . . . . . . . . . . .1
Application . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Typical Installation . . . . . . . . . . . . . . . . . . . . .2
Pre-Installation Check . . . . . . . . . . . . . . . . . .2
Pump Location . . . . . . . . . . . . . . . . . . . . . . . .3
Pipework . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Pump Connections . . . . . . . . . . . . . . . . . . . . .6
INDEX
. . . . . . . . . . . . . . . . . . . . . . . .Page No
Electrical Installation . . . . . . . . . . . . . . . . . . .10
Commissioning . . . . . . . . . . . . . . . . . . . . . . . .13
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . .15
Technical Specification . . . . . . . . . . . . . . . . . .18
Noise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Trouble Shooting Guide . . . . . . . . . . . . . . . . .19
Environment Protection . . . . . . . . . . . . . . . . .20