Stuart Turner Aquaboost iBoost +200 Скачать руководство пользователя страница 8

- 8 -

4 INSTALLATION

4.11 

Mains water connection to iBoost:

 The 200 is to be permanently    

 

connected to the mains water supply using rigid pipe or suitably sized and rated  

 

flexible hose to comply with current building and plumbing regulations.

 

The water tank fill valve has a G ½ male threaded fitting; a suitable 90

o

 elbow    

 

type fitting must be used.  When tightening ensure the fill valve within the tank    

 

is not rotated.  If the valve is rotated it may not function correctly with the risk of   

 flooding.
 

Ensure there is a demountable joint in the pipe to allow the removal of the iBoost  

 

if needed (see Fig. 15).

4.12 

Water outlet pipework:

 

The 200 is supplied with a kit for connecting it to an iBoost 200 unit,  

 

 

side to side.

 

If a greater distance between the units is required then a longer hose will need to  

 

be sourced.

4.13 

Connection to overflow/warning pipe:

 The overflow fitting is designed to use  

 

1 ¼ " (35 mm OD) plastic waste pipe.  Ensure there is a demountable joint in the  

 

pipe to allow the removal of the iBoost if needed (see Fig. 15). The overflow must  

 

be free to vent to atmosphere either via a tundish or a dedicated external pipe.

 

The overflow for the +200 unit is to be kept separate from the existing iBoost 200  

 

unit’s overflow.

4.14  The iBoost is intended to be installed as a freestanding unit with its back  

 

 

to a wall.

 

All the services are connected to the iBoost via a plumbing access window at the  

 

back of the unit, the installation is conducted in 3 simple steps.

 

Prior to installation remove the screw on the top of the unit and pull the corner of  

 

the front cover to remove it and retain them in a safe place.

 

Step 1 Preparation:

 

a)  If connecting to an already installed iBoost 200 unit, then drain the water out  

 

 

of the tank.  It needs to be empty in order to connect the +200 unit to it.

 

b)  The kit provided is for side connection only, back connection is possible  

 

 

 

with additional fittings and longer hose (not supplied).  The supplied hose    

 

 

provides a maximum gap between the units of approximately 262 mm (from   

 

 

tank to tank).  Measure the gap and check there is enough space to fit the    

 

 

secondary unit in place.

262

536

Fig. 4

iBoost 
+200 unit

iBoost 
200 unit

Содержание Aquaboost iBoost +200

Страница 1: ...contains important guarantee maintenance and safety information Read this manual carefully before commencing installation This manual covers the following products CE compliant product iBoost 200 Pt...

Страница 2: ...ten consent of Stuart Turner Limited z z This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and k...

Страница 3: ...NTENTS Page Checklist 4 Important Facts read before commencing installation 5 Location 6 Key Features 7 Installation 8 Commissioning 14 Maintenance 15 Technical Specification 17 Trouble Shooting 18 Gu...

Страница 4: ...tion Qty iBoost 200 1 Jubilee clip 2 Retaining strap 1 Hose connector 2 M6 screw 1 Tank connector 2 Hose cover 1 Instruction book 1 Hose 1 Installation book 1 O ring 52 mm ID 2 A E C B D F G H I J K F...

Страница 5: ...ure pipework to the iBoost this will cause damage and possible leakage 1 15 Flux Solder joints must be completed and flux residues removed prior to iBoost installation flux damage will void any warran...

Страница 6: ...be lower than 7 bar lower supply inlet pressures will reduce the tank fill rate 2 15 Ambient temperature The iBoost must be sited in a location where the ambient temperature does not exceed 30 o C se...

Страница 7: ...KEY FEATURES iBoost 200 iBoost 200 CAT 5 Label Part No Serial No Overflow Tank Tank access cover Mains water connection Fig 2 Retaining strap Cover retaining screw location Fig 3 Drain valve Weir aper...

Страница 8: ...pe to allow the removal of the iBoost if needed see Fig 15 The overflow must be free to vent to atmosphere either via a tundish or a dedicated external pipe The overflow for the 200 unit is to be kept...

Страница 9: ...fitting at 89 mm diameter b Cut a hole in both tanks using a 65 mm diameter hole cutter using the centre points marked previously Take care not to allow debris to fall into the tank and keep cut edge...

Страница 10: ...s in order to aid sealing f The whole assembly can now be pulled into position by pulling gently on the wire holder Note Take care to see that the body is in the centre of the hole using the outer mar...

Страница 11: ...l alongside the existing unit where the iBoost 200 is to be installed approximately 262 mm away from existing tank Ensure the floor level of the template is level and resting on the surface the iBoost...

Страница 12: ...compression were shown in Fig 15 The positioning of these fittings allow the iBoost to be removed without cutting pipes or draining the system Fig 14 Mains water supply Pumped water supply connection...

Страница 13: ...nector With the jubilee clip into position tighten to secure hose h Spllit the hose cover apart at the join and push over the hose 4 15 It is recommended that at least one drinking water tap is connec...

Страница 14: ...dies are removed from elsewhere in the system Fill the system and check for leaks refer back to the iBoost 200 manual for priming and starting of the pump 6 12 Water Supply Always ensure that water su...

Страница 15: ...time the tank should be drained and flushed through The tank should be cleaned on an annual basis to protect against bacterial growth If the iBoost is installed in a rental property it must be maintai...

Страница 16: ...the float assembly on the arm of the fill valve down see Fig 21 Access the float fill valve by removing the lid of the tank see Section 3 Key Features This is done by loosening the M6 retaining screw...

Страница 17: ...p Type AF Type AB Performance Maximum inlet pressure tank fill valve 7 bar 700 kPa Maximum static outlet head 15 metres Ambient air temperature Min Max 4 o C 30 o C Water tank Nominal size 220 litres...

Страница 18: ...ING GUIDE 8 11 Environment Protection Your appliance contains valuable materials which can be recovered or recycled At the end of the products useful life please leave it at an appropriate local civic...

Страница 19: ...orrect installation improper use unauthorised repair normal wear and tear and defects which have a negligible effect on the value or operation of the product Reasonable evidence must be supplied that...

Страница 20: ...s an installer link on our homepage at www stuart turner co uk and complete a short form which will enable visitors to find your contact details on our web site installer finder Alternatively use your...

Отзывы: