9  TROUBLE SHOOTING GUIDE

9.11 

Controller alarm code

 

In case of multiple fault, scroll with the buttons 

 (plus) or 

 

(minus) to visualize the fault sequence.  In case of thermal 
block it is advised to check the causes that have created the 
problem before restart the pump operation.

No

Description

Causes

ER01

No water

The device is in failure due to no water.
The system try to restart automatically.
- One attempt every 10 minutes for 6 times.
- One attempt every hour for 24 times.
- One attempt every 24 hours for 30 times.

Er02

Pressure transducer fault

Cable not connected, broken connection, pressure transducer 
damaged.

Er03

Low supply voltage

Supply voltage lower then 190 V.
- The system automatically restart when the clamp voltage is 
higher than 190 V.

Er04

High rectified voltage

Supply voltage higher than 250 V.
- The system automatically restart when the clamp voltage is 
lower than 250 V.

Er05

Memory failure

Contact Stuart Turner.

Er06

Overcurrent in the electro pump motor

Contact Stuart Turner.

Er07

Overcurrent in the frequency converter

Contact Stuart Turner.

ER08

Direct short circuit controller on output

Contact Stuart Turner.

Er09

Overheating

Ensure good air flow around the booster set

Er10

Overheating of the power module

Contact Stuart Turner.

Er11

Low voltage 24 V

Contact Stuart Turner.

Er12

Stop for float switch intervention

The system will restart with a delay defined by AP19 from the 
state variation of the float switch.  The control panel for remote 
alarm not report this alarm.

Er13

Internal hardware error

Contact Stuart Turner.

Er14

Duty-assist mode communication error

Check the RS 485 connection or that both pumps are 
enabled.

Содержание ABB V150-45-2V-1

Страница 1: ...nce and safety information Read this manual carefully before commencing installation This manual covers the following products ABB V150 45 2V 1 Pt No 46684 ABB V260 65 2V 1 Pt No 46687 ABB V150 60 2V...

Страница 2: ...or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with t...

Страница 3: ...he pump removed from its packaging check for any damage prior to installation If any damage is found contact Stuart Turner Ltd within 24 hours of receipt AB B V 150 45 2 V 1 No of pumps Metres head va...

Страница 4: ...nt Product Performance Performance curve indicates maximum performance both pumps running 0 1 2 3 4 5 6 7 8 9 0 10 20 30 40 50 60 70 80 90 100 0 50 100 150 200 250 300 Head bar HEAD metres FLOW l min...

Страница 5: ...t supplied 1 16 Flux Solder joints must be completed and flux residues removed prior to pump installation flux damage will void any warranty 1 17 Pipework design Care should be taken in the design of...

Страница 6: ...booster set has been installed and connected to the suction and discharge pipework before installing the pressure vessel On no account should the pressure vessel be used to manouvre the booster set in...

Страница 7: ...e mounted as close to the water source as possible on a level surface and if the plant room has a chance of flooding it is recommended that the unit is installed on a suitable plinth capable of taking...

Страница 8: ...See Fig 1 to identify the suction and discharge connections 2 23 Isolating valves Separate system isolating valves non restrictive must be fitted to the suction and discharge of the pump set on the sy...

Страница 9: ...el is supplied loose this must be fitted to the connection on the discharge pipework The connection is sealed with two O rings within the end of the connection ensure the O rings are not damaged durin...

Страница 10: ...be permanently earthed via the supply cord which must be correctly connected to the earth point located in the terminal box The inverter should be protected separately against ground fault 4 16 Addit...

Страница 11: ...ation Remote Optional MS HBC aM AquaBoost Controller Pump VSD2 Pressure Transducer Aquaboost Booster Set range Fig 5 Note This switch does not isolate all connections to this panel Isolate elsewhere b...

Страница 12: ...al cables Take care not to damage the electronic cards z z Failure to comply with the safety regulations not only causes risk to personal safety and damage to the equipment but also invalidates the wa...

Страница 13: ...rogramming menu scroll up Programming confirm Increase or scroll left Decrease or scroll right 5 11 Screen format Fig 6 Fig 7 Auto mode Manual mode Set up mode activated Alarm Sensor state Pump state...

Страница 14: ...ducer connected to that controller Pump state Indicates if the pump is running or in stand by state Duty assist mode Indicates that the controls are in duty assist mode The 2 upper symbols indicate if...

Страница 15: ...of both controllers see Fig 8 5 14 Remote alarm connection Using terminals 10 and 11 a remote alarm can be connected to both controllers see Fig 9 The remote alarm can be used to signal error on the...

Страница 16: ...level the pumps will re start automatically after a pre set time delay AP19 For entering the programming mode see 5 24 5 16 Parameters On the controller the following information is displayed Pump st...

Страница 17: ...ss this menu Password entry is required contact PumpAssist for assistance AE Advanced parameters this allows display of the secondary parameters which can be useful for system diagnostics Example AE01...

Страница 18: ...amic 1 fast dynamic 5 slow dynamic 3 AP09 Duty assist mode oFF UU duty assist mode with double inverter UF duty assist mode with an inverter oFF AP010 Master Slave setting MAS master SLA slave SLA AP0...

Страница 19: ...voltage V 195 SA015 Nominal voltage V 220 5 23 MAn Fixed speed mode activation To enter password is required contact PumpAssist for assistance on 44 0 800 31 969 80 No Description Factory settings Mod...

Страница 20: ...is adequate to meet the demand Ensure the pump chambers are full of water before starting the unit Failure to do this could result in seal damage To ensure dry running does not occur the pumps must be...

Страница 21: ...set pressure UP05 a Press to access menu b Using and find menu UP press to enter c Using and find parameter UP05 press to enter d Using and adjust the set pressure press to enter During this process t...

Страница 22: ...ble volume of water will be released as the vessel discharges d With the drain valve open unscrew the black plastic cover to reveal the Schrader valve Check air charge at Schrader valve Fig 12 using a...

Страница 23: ...eller Stainless steel Performance Performance See Curve Fig 2 Minimum static inlet pressure 1 metre Maximum static inlet pressure 10 metres Maximum working pressure 16 bar Maximum ambient air temperat...

Страница 24: ...24 litres Diaphragm Tank Water Capacity 12 litres Materials Pump body Stainless steel Impeller Stainless steel Performance Performance See Curve Fig 2 Minimum static inlet pressure 1 metre Maximum st...

Страница 25: ...ltage is higher than 190 V Er04 High rectified voltage Supply voltage higher than 250 V The system automatically restart when the clamp voltage is lower than 250 V Er05 Memory failure Contact Stuart T...

Страница 26: ...ansducer fault Check wiring to transducer transducer function error Er02 Stopped due to tank level float switch if fitted Check water float switch operation if fitted error Er12 Power failure has stop...

Страница 27: ...ar and defects which have a negligible effect on the value or operation of the pump Reasonable evidence must be supplied that the product has been purchased within the guarantee term prior to the date...

Страница 28: ...2008 108EC IT IS HEREBY CERTIFIED THAT THE STUART ELECTRIC MOTOR DRIVEN PUMP AS SERIAL NUMBER BELOW COMPLIES WITH THE ESSENTIAL REQUIREMENTS OF THE ABOVE E E C DIRECTIVES RESPONSIBLE PERSON AND MANUFA...

Отзывы: