23
9.7
Priming
•
Never operate pump with inlet and/or outlet isolating valves in
the closed position. Damage will occur!
•
The tank must be filled with water before starting the pump.
1.
Turn on the service valves nearest the iMatic and allow the air to vent
from the system.
2.
Turn on the iMatic and allow the pump to build up pressure purging the
air from the system.
3.
Open all the service valves (including flushing WCs) in turn to fully
purge the air from the system.
9.8
Starting
1.
Ensure all outlets are closed, turn power supply ‘on’ - pump will start,
pressurise the system then stop.
2.
Open and close all outlets in turn associated with the pump, (including
w/c systems) allowing water to flow from each outlet until all air is
purged. As each outlet is opened and closed, the pump will start and
stop respectively.
Note: After closing the outlet there will be a small time delay before the
pump stops, which is normal.
3.
Any tap or control valve within the system when opened and closed will
now turn the iMatic on/off, there will be a delayed start due to the
water stored in the pressure vessel. Providing this is the case the
system is now operating correctly.
4.
Carefully check pump and pipework for leaks whilst pump running and
stationary before leaving the installation unattended.
9.9
For Further Technical Support
Phone the Stuart Turner TechAssist team on +44 (0) 800 31 969 80. Our staff are
trained to help and advise you over the phone.