11
7.4
Unit Location
The iMatic is intended to be installed as a freestanding unit with its back to a wall.
1.
Slide the iMatic into position in front of the services leaving
approximately 20 mm gap between the iMatic and the wall behind.
2.
Connect the services using isolation valves and demountable fittings
(push-fit or compression). The positioning of these fittings should allow
the iMatic to be removed without cutting pipes or draining the system.
7.5
Drinking Water Tap
It is recommended that at least one drinking water tap is connected into the un-
pumped mains water supply (typically a kitchen sink), so the water supply is
maintained in the event of a failure of the pumped supply.