18
9.2
Start Up (Single Controller)
Be sure that the pump is correctly primed.
FAILURE led light will be ON. Wait for 10 seconds while the iMatic conducts an
autotest. Once it finishes, led light FAILURE is OFF and led light LINE is ON. The
LCD screen will show message “IMATIC” and the language display of the
configuration mode.
The device is ready to be configured.
9.3
Start Up (Twin Controller)
During the configuration process it is possible to select which device is the
MASTER.
CONFIGURATION OF THE MOTOR SUPPLY (single-phase / three-phases):
The device is suppliedby default for connection to an three-phase motor. If it must
be connected to a single-phase motor the following steps should be followed:
The electrical connection will be done following the indications of the section
“ELECTRICAL CONNECTION” for single-phase motors. (see scheme fig.6).
Once the device is connected, we will press simultaneously the pushbuttons,
MENU + ENTER, to enter in the expert menu. In this menu can be modified
variables of the program (integration, acceleration and deceleration) and also to
be chosen the type of supply of the motor. It is not recommended the
modification of the variables.
Values are changed using pq and pushing ENTER to memorize changes. Use
ENTER 3 times to confirm the initial values of the program variables (integration,
acceleration and deceleration) and next, using the pushbuttons pq we will choose
single-phase or three-phase. Push ENTER to quit the expert menu. Example:
The device must be unswitched from the electric supply and wait until the LCD
will be off. Turn on the device again.