Stropuva Pellet boiler Series Скачать руководство пользователя страница 2

SAFETY 

1.1.

 

Notes about this instruction 

This manual contains important information about proper installation, testing, use and maintenance of boiler. Manual 
of installation and use is created for installers, who have special education and good knowledge about use of heating 
systems. 
Indication related to use of boiler are dedicated to user and are clearly marked.  
In this document boilers of solid fuel are generally called boilers.  Text clearly identifies differences of different versions 
of the unit.  

 

1.2.

 

Intended use 

Before connecting the boiler to heating system it is necessary to read this manual carefully and to make sure that all 
components are working correctly and none of them are missing.  
 
Stropuva “Granulinis” is steel boiler with automatic pellet feed (without helical conveyer), fired using 6 mm – 8 mm 
wood pellets. They are designed for heating of apartments, premises, small shops, repair shops.   Temperature of water 
in boiler is 85 

O

C and highest pressure of heat transfer medium is – 0,15 MPa. 

 
Integral part of boiler “Granulinis” is electronic control block. 
 
Company reserves the right to change the construction and assures that these changes will not severely affect the firing 
process or operation of boiler. 
 
Boiler “Granulinis” meets the requirements of European standards EN 303-5, EN 12809, provisions of Lithuanian laws 
and EU directives related to safety of products. 
Installation and operation of boiler should be done according to country’s regulations and indications of this manual.  

 

1.3 Meaning of symbols 

 

Text of safety related information is marked with warning triangle and written in grey space.  

 
Word 

Attention! 

Means that there is a risk of slight damage to property. 

 
Word 

Warning 

means that there is likely possibility of slight injury or severe damage to property. 

__________________________________________________________________________________________________ 
 

Text marked with this symbol, provides advice. It will be separated from other text by upper and 
lower horizontal lines. 
 

__________________________________________________________________________________________________ 
 
 
 

Содержание Pellet boiler Series

Страница 1: ...Pellet boiler TECHNICAL PASSPORT INSTALLATION AND MAINTENANCE MANUAL...

Страница 2: ...ghest pressure of heat transfer medium is 0 15 MPa Integral part of boiler Granulinis is electronic control block Company reserves the right to change the construction and assures that these changes w...

Страница 3: ...ng other manufacturer s parts __________________________________________________________________________________________________ DANGER Danger of poisoning with carbon monoxide If boiler uses air from...

Страница 4: ...ler when it is working Boiler s operating temperature must not exceed 85 o C it must be constantly observed It is forbidden to use liquids for ignition of fire or to increase the power of boiler Remov...

Страница 5: ...wood oak wood panels HOBREX VERZALIT Formica C2 average flammability Wood of pine larch and spruce also products covered with such wood C2 flammable Asphalt cardboard cellulose materials bituminized p...

Страница 6: ...nd water column is larger than 15 m spiral cooler with permeability of 1500 l h needs to be installed Pressure of cold water supplied to safety device cannot be lower than 2 bar Water flow from cooler...

Страница 7: ...d in rated data plate Parts of pellet boiler 1 Decoration of boiler 2 Burner of pellets 3 Pipe of heated water 4 Pipe of returning water 5 Heat exchanger with flowing water inside of it 6 Thermal insu...

Страница 8: ...ntact thermostat installed on piping fed by boiler For controlling temperature of outgoing water and for controlling the fan Airflow regulator 3 installed in burner Secondary air supply in into burnin...

Страница 9: ...00 1300 Standard load of fuel kg 30 60 90 Weight kg 82 87 92 Fuel consumption at rated power Kg h 4 0 4 0 4 0 Required chimney draft Pa 20 25 20 25 20 25 Power supply 230 V 6 A 230 V 6 A 230 V 6 A Max...

Страница 10: ...ase of excessive draft there will be increase in fuel consumption and in extreme cases there is a chance of overheating the device This flaw can be eliminated by installing draft limiter Chimney sweep...

Страница 11: ...vice need 230 V power supply therefore installation works must be carried out by a person with appropriate knowledge skills and who meets additional requirements of Country in which the boiler is inst...

Страница 12: ...lete manner 45 degrees When closing the pellets close the door If is not burning repeat After burning the burner after half an hour observe the smoke from the chimney if the smoke is dark it is too li...

Страница 13: ...roximately say 25 C T If the boiler thermostat switches off the burner to the remaining room before the required level set the temperature higher to 2 3 C If there is not enough heat in the room incre...

Страница 14: ...r will not be used for longer period of time for example when heating season is over use up all the fuel from the bunker Heat exchange medium mustn t be removed from the heating system before the down...

Страница 15: ...chimney because chimney s condition must be thoroughly inspected all damage must be repaired Also user needs to get permission from competent administration institutions to continue to use the chimne...

Страница 16: ......

Страница 17: ......

Страница 18: ...the requirements of Country in which it is operated Also follow these instructions when using the boiler 1 These actions have to be carried out before doing any maintenance work a Turn of the fan or...

Страница 19: ...ightness was inspected and it was confirmed as effective and suitable for use 1 If user follows the instructions of installation operation and maintenances indicated in user manual distributor provide...

Страница 20: ...stributor informs the manufacturer or user fills out request and after filling out a complaint provides a copy of document proving the purchase of product If passport of device is lost user is respons...

Страница 21: ...s product I believe that shortcoming listed in complaint were caused by defects of your product I ask you to send your representatives to inspect the connected device to determine and remove the defec...

Страница 22: ...ure of device copy of this passport is sent to seller or distributor Original copy of passport must be presented to authorized technician who comes to repair the failure Model Serial No Rated power Pu...

Отзывы: