Stropuva Pellet boiler Series Скачать руководство пользователя страница 14

Attention! 

When device is in operation, cover of tank must be fully closed. 

 

Attention! 

In order to fill fuel tank with pellets, contact thermostat must be set to zero and fan must be 
turned off. 

 

If fuel meets the standards and recommendation of manufacturer, ash will fall into ash chamber. If fuel doesn’t meet 
the standards, requirements and manufacturer’s instructions, there can be malfunctions of burning process, buildup of 
condensate, soot and resin.  

7.4. Setting of thermostat of premises 

Electronic programmable thermostat is designed for adjustments of temperature in the premises. In order to find out 
how to program the thermostat, read its manual, which is included with manual of every boiler. 

7.5. How to stop the flow of pellets 

 

 

   

7.6. Shutting down the boiler 

When the bunker is out of fuel or fire of the burner is out, turn of the fan by following the instructions (set the contact 
thermostat to 0 

o

C), remove the ash and soot out of boiler. If boiler will not be used for longer period of time (for 

example, when heating season is over), use up all the fuel from the bunker.  Heat exchange medium mustn’t be 
removed from the heating system before the downtime period. 

7.7. Emergency shut down of boiler 

In cases of boiler malfunction, for example, when heat exchanger medium exceeds 100 

O

C temperatures (when heat 

exchanger medium is partly evaporated or when sounds, made by boiler, are heard in heating system), cracked pipes, 
radiators, valves or if there is other danger of unsafe operation of boiler, user needs to: 

 

Assure maximum cooling of boiler room by opening doors, windows, hatches, loading holes, etc. 

 

Turn off the fan. 

 

Eliminate the problem. 

 

Check the level of heat exchanger medium in heating system and after boiler cools down, fill it up if needed. 

 If there is a need to pour some of cold heat exchanger medium into cold one (after losing large amounts), while boiler is 
working, wait till boiler cools down, fill up the system of heat exchanger medium, carry out preparation works and 
reignite the boiler. If cold heat exchanger medium touches hot wall of boiler, there is possibility of damage to the boiler. 

Содержание Pellet boiler Series

Страница 1: ...Pellet boiler TECHNICAL PASSPORT INSTALLATION AND MAINTENANCE MANUAL...

Страница 2: ...ghest pressure of heat transfer medium is 0 15 MPa Integral part of boiler Granulinis is electronic control block Company reserves the right to change the construction and assures that these changes w...

Страница 3: ...ng other manufacturer s parts __________________________________________________________________________________________________ DANGER Danger of poisoning with carbon monoxide If boiler uses air from...

Страница 4: ...ler when it is working Boiler s operating temperature must not exceed 85 o C it must be constantly observed It is forbidden to use liquids for ignition of fire or to increase the power of boiler Remov...

Страница 5: ...wood oak wood panels HOBREX VERZALIT Formica C2 average flammability Wood of pine larch and spruce also products covered with such wood C2 flammable Asphalt cardboard cellulose materials bituminized p...

Страница 6: ...nd water column is larger than 15 m spiral cooler with permeability of 1500 l h needs to be installed Pressure of cold water supplied to safety device cannot be lower than 2 bar Water flow from cooler...

Страница 7: ...d in rated data plate Parts of pellet boiler 1 Decoration of boiler 2 Burner of pellets 3 Pipe of heated water 4 Pipe of returning water 5 Heat exchanger with flowing water inside of it 6 Thermal insu...

Страница 8: ...ntact thermostat installed on piping fed by boiler For controlling temperature of outgoing water and for controlling the fan Airflow regulator 3 installed in burner Secondary air supply in into burnin...

Страница 9: ...00 1300 Standard load of fuel kg 30 60 90 Weight kg 82 87 92 Fuel consumption at rated power Kg h 4 0 4 0 4 0 Required chimney draft Pa 20 25 20 25 20 25 Power supply 230 V 6 A 230 V 6 A 230 V 6 A Max...

Страница 10: ...ase of excessive draft there will be increase in fuel consumption and in extreme cases there is a chance of overheating the device This flaw can be eliminated by installing draft limiter Chimney sweep...

Страница 11: ...vice need 230 V power supply therefore installation works must be carried out by a person with appropriate knowledge skills and who meets additional requirements of Country in which the boiler is inst...

Страница 12: ...lete manner 45 degrees When closing the pellets close the door If is not burning repeat After burning the burner after half an hour observe the smoke from the chimney if the smoke is dark it is too li...

Страница 13: ...roximately say 25 C T If the boiler thermostat switches off the burner to the remaining room before the required level set the temperature higher to 2 3 C If there is not enough heat in the room incre...

Страница 14: ...r will not be used for longer period of time for example when heating season is over use up all the fuel from the bunker Heat exchange medium mustn t be removed from the heating system before the down...

Страница 15: ...chimney because chimney s condition must be thoroughly inspected all damage must be repaired Also user needs to get permission from competent administration institutions to continue to use the chimne...

Страница 16: ......

Страница 17: ......

Страница 18: ...the requirements of Country in which it is operated Also follow these instructions when using the boiler 1 These actions have to be carried out before doing any maintenance work a Turn of the fan or...

Страница 19: ...ightness was inspected and it was confirmed as effective and suitable for use 1 If user follows the instructions of installation operation and maintenances indicated in user manual distributor provide...

Страница 20: ...stributor informs the manufacturer or user fills out request and after filling out a complaint provides a copy of document proving the purchase of product If passport of device is lost user is respons...

Страница 21: ...s product I believe that shortcoming listed in complaint were caused by defects of your product I ask you to send your representatives to inspect the connected device to determine and remove the defec...

Страница 22: ...ure of device copy of this passport is sent to seller or distributor Original copy of passport must be presented to authorized technician who comes to repair the failure Model Serial No Rated power Pu...

Отзывы: