Recharging the Battery 

WARNING

 

 

Always ensure that internal battery is fully charged. Do not overcharge the battery. 

 

Leaving a battery in a discharged state or without recharging every 90 days may result in 
permanent damage to the battery and poor boosting performance. 

 

Do not use the AC or DC outlets while the power pack is being charged. Doing so may damage 
the charging adapter. 

 

Do not attempt to recharge the internal battery if it is frozen. 

 

Use the supplied AC charger to recharge the unit. 

 

Recharge the unit every 90 days to maintain maximum battery capacity and extend unit life.  

Recharging the Jumpstarter 

1.  Turn off all accessories before recharging. 

2.  Plug one end of included AC charger into charging input port of the jumpstarter and other end to 

115 V AC electrical socket. 

3.  The charging status will be displayed on LCD screen. 

Do not unplug the power cord until the battery is fully charged. It may take 30 hours or more to fully 
recharge the jumpstarter battery provided the voltage is 115 V AC.  

Maintenance 

Maintain the jumpstarter by adopting a program of conscientious repair and maintenance in 
accordance with the following recommended procedures. It is recommended that the general 
condition of any jumpstarter be examined before it is used. Keep your jumpstarter in good repair. 
Keep handles dry, clean, and free from oil and grease. The following chart is based on a normal 
operation schedule. 

 
 

Maintenance Interval 

Maintenance Point 

Before operating or after using

 

Clean the exterior surface of the jumpstarter with a damp cloth 
to prevent accumulation of dust and dirt. 

After using  

Make sure USB/LED/DC is OFF. 

Make sure ON/OFF Power Switch to OFF position after use. 

Make sure disconnecting the 12V DC appliances after use to 
avoid over discharge of jumpstarter

’s internal battery. 

Make sure the plastic covers on the 12V DC outlet are closed 
after use. 

Extending battery lifespan 

Recharge the battery at least once every 90 days. This will 
extend the durability and efficiency of the battery. 

 

 

Содержание 500A 53013

Страница 1: ...arter Owner s Manual WARNING Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating Failure to follow the safety rules and other basic safety precautions may result in serious personal injury Items 53013 53014 ...

Страница 2: ...ant that you read the entire manual to become familiar with this product before you begin using it This jumpstarter is designed for certain applications only Northern Tool Equipment is not responsible for issues arising from modification or improper use of this product such as an application for which it was not designed We strongly recommend that this product not be modified and or used for any a...

Страница 3: ...cifications 53014 4 Important Safety Information 5 Specific Operation Warnings 7 First Aid 7 Main Parts of Product 8 Before Each Use 8 Operating Instructions 9 Recharging the Battery 12 Maintenance 12 Troubleshooting 13 Parts List 13 Replacement Parts 13 Limited Warranty 14 ...

Страница 4: ...nce Abbreviations and Acronyms A Ampere mA Milli Ampere AC Alternating Current V Volt Ah Amp hours LED Light Emitting Diode DC Direct Current Specifications 53013 12V DC Power Section Boost Ampere 500 Instantaneous Cranking Amps Battery 20Ah 12V Sealed Lead acid Battery Jump Start Cables size length 6AWG 2Ft AC Charging Adapter 15V 400mA 12V DC Power Socket 20A max fuse protected USB Output 3 1A S...

Страница 5: ...quipment for a purpose for which it was not intended Industrial or commercial applications must follow OSHA requirements WARNING This jumpstarter may contain chemicals known to the State of California to cause cancer birth defects or other reproductive harm WARNING WORK AREA SAFETY Inspect the work area before each use Keep work area clean dry free of clutter and well lit Cluttered wet or dark wor...

Страница 6: ...s wider than the other This plug will fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician to install a polarized outlet Do not change the plug in any way Double insulation eliminates the need for the three wire grounded power cord and grounded power supply system Avoid body contact with ground...

Страница 7: ...atches when working with a lead acid battery A lead acid battery can produce a short circuit current high enough to cause injury Always battery clamps when not in use Never touch battery clamps together This can cause dangerous sparks power arcing and or explosion Always disconnect the negative jumper cable first followed by the positive jumper cable Do not expose the battery to fire or extreme he...

Страница 8: ...oosting cable 4 Work light off button 5 Work light SOS 6 Work light Strobe 7 Work light on button 8 12V DC sockets 9 Handle 10 Work light 11 LCD display 12 Charging port 13 4 USB ports 3 1A share for 2 USBs 14 Battery check button 15 On Off switch for left 2 USBs 16 On Off switch for right 2 USBs 17 12V DC On OFF switch 18 Negative boosting cable 19 Reverse connection indicator red 20 Correct conn...

Страница 9: ...ained and not consumer replaceable Batteries must be disposed of properly when they no longer hold a charge Operating Instructions WARNING SPARK AND EXPLOSION HAZARD Risk of explosive gases Working in the vicinity of a lead acid battery is dangerous Batteries generate explosive gases during normal battery operation Do not smoke use matches or a cigarette lighter while near batteries Do not handle ...

Страница 10: ...light has multiple functions Press the desired light function button to select the desired function 3 Turn off the LED light after use Failure to do so may discharge the internal battery to dead 4 Recharge the jumpstarter immediately after use Jumpstarting an Engine 1 Make sure your vehicle is a negative ground system If it is a positive ground system vehicle or you are unsure please consult the v...

Страница 11: ...ons carefully for boosting your vehicle The instructions may be different from those mentioned for other boosting products or cables Do not crank the engine for more than 5 seconds The jumpstarter feature is designed only for short term operation Failure to comply may cause damage to the device CAUTION EQUIPMENT DAMAGE Use only the supplied boost cables to boost a vehicle that has a 12V starting b...

Страница 12: ...charged It may take 30 hours or more to fully recharge the jumpstarter battery provided the voltage is 115 V AC Maintenance Maintain the jumpstarter by adopting a program of conscientious repair and maintenance in accordance with the following recommended procedures It is recommended that the general condition of any jumpstarter be examined before it is used Keep your jumpstarter in good repair Ke...

Страница 13: ...arger is low Replace the 115 V AC charger The internal battery is permanently damaged Check the battery at a car maintenance workshop Switches are in the ON position or DC loads are connected Place all switches in OFF position and disconnect all DC loads The alarm sounds and reverse polarity indicator is ON The jump start cables are connected incorrectly Connect the jump start cables the correct w...

Страница 14: ...y claim contact Us at 1 800 222 5381 identify the product by make and model number and follow the claim instructions that will be provided The product and the purchase receipt must be provided to Us in order to process Your warranty claim Any returned product that is replaced or refunded by Us becomes our property You will be responsible for return shipping costs or costs related to Your return vi...

Страница 15: ...Page 15 of 15 Distributed by Northern Tool Equipment Company Inc Burnsville Minnesota 55306 www northerntool com Made in China ...

Отзывы: