background image

   

 

 

 

 

Key Ring Controller KFOB2 

Quick Start 

 

Please refer to the chapters below for detailed information about all aspects of the products usage.

 

The device operates in normal control mode or in management mode. 

Pushing  all  four  buttons 

for 5 sec. will turn the device into management mode

 (indicated by blinking green LED). The 

management  mode  will  time  out  after  10  seconds  if  no  further  button  is  pushed. 

Button  3 

confirms  standard  inclusion  or  exclusion

  started  by  a  primary  controller,  button  2  issues  a 

Node Information Frame or wakeup notification, button 4 is used to add devices into association 
groups and 

button 1 confirms inclusion or exclusion in NWI (network wide inclusion) mode. 

 

 
 

What is Z-Wave? 

This 

device 

is 

equipped 

with 

wireless 

communication  complying  with  the  Z-Wave 
standard.  Z-Wave  is  the 

international  standard 

for  wireless  communication 

in smart homes and 

buildings.  It  is  using  the 

frequency  of  868.42 

MHz (EU) or 908 MHz (US)

 to realize a very stable 

and  secure  communication  between  devices  of 
different  origin,  type  and  brand.  Each  message  is 
reconfirmed (

two-way  communication

) and every 

mains  powered  node  can  act  as  a  repeater  for 
other  nodes  (

meshed  network

)  in  case  the 

receiver  is  not  in  direct  wireless  range  of  the 
transmitter. 

Z-Wave 
differentiates 
between 
Controllers 

and 

Slaves. 

Slaves 

are 

either 

sensors 

(S)

 trans-

mitting metered or 
measured  data  or 
actuators 

(A)

 capable  to  execute  an  action. 

Controllers  are  either  static  mains  powered 

controllers 

(C)

 also  referred  to  as  gateways  or 

mobile  battery  operated  remote  controls 

(R)

.  This 

results  in  a  number  of  possible  communication 
patterns within a Z-Wave network that are partly or 
completely supported by a specific device. 

 

1.  Controllers control actuators. 
2.  Actuators report change of status back to 

controller. 

3.  Sensors report change of status of 

measured values to controller. 

4.  Sensors directly control actuators. 
5.  Actuators control other actuators. 
6.  Remote controls send signals to static 

controllers to trigger scenes or other 
actions. 

7.  Remote controls control other actuators. 

Product description 

The  Z-Wave.Me  Key  Fob  is  a  Z-Wave  device  that 
can  both 

control  other  Z-Wave  devices

  and 

activate  predefined  scenes  in  an  IP  gateway

Although  it  is  controlling  other  devices,  the  KFOB 
can’t  act  as  Z-Wave  network  controller  (primary  or 
secondary) and will always need a Z-Wave network 

Содержание KFOB2

Страница 1: ...y communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter Z Wave differentiates between Controllers and Slaves Slaves are either sensors S trans mitting metered or measured data or actuators A capable to execute an action Controllers are either static mains powered controllers C also ref...

Страница 2: ...respective chapters below Button 3 Standard Inclusion Exclusion Mode The device is included or excluded from a controller in direct wireless range Any button press stops the mode Performing an exclusion of the device from a network resets the device into its factory default Button 4 Association Set To assign target devices to one of the four association groups Refer to the manuals section about as...

Страница 3: ...Control of associated devices using ON OFF DIM UP and DIM DOWN This is the default mode No 1 Devices in association groups are controlled using Basic ON and OFF commands and Dim Start Stop commands This mode implements the communication pattern 7 The parameter value No 2 disables the use of Dim commands Control of Devices in proximity Basic ON OFF and Dim Start Stop commands are sent to the device...

Страница 4: ... minimum allowed wakeup time is 240s but it s strongly recommended to define a much longer interval since the only purpose of a wakeup should be the reporting of the battery status or an update of the child protection settings Defining Node id of 0 as a destination of the Wakeup Notification will disable the periodical wakeup function entirely It is possible to set the node ID to 255 to send wakeu...

Страница 5: ...nate the process Configuration Parameters Z Wave products are supposed to work out of the box after inclusion however certain configuration can adapt the function better to user needs or unlock further enhanced features Pair Mode for Button 1 and 3 Parameter Number 1 Pair Mode for Button 2 and 4 Parameter Number 2 Value Description 0 Separately 1 In pair without double clicks Default 2 In pair wit...

Страница 6: ...llation costs removal cost or reinstallation cost For information on additional devices please visit us online This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can ...

Отзывы: