9
MA_325-40D-TP_A9_181015_en
Fig. 1
3.1.2
Re-mount the needle plate in reversed order.
Remounting the needle plate
3.2
After removing height stop limit lever for the hook, thread spreader (if existing),
stitch plate, bevel wheel protective cover (rear of head) and bevel wheel
240.0020, the hook can be withdrawn to the front side.
Replacing is executed in reverse sequence,
Removing and inserting hook
Observe following indications:
a)
Distance between hook point and a needle size 110 must be 0.1 mm.
Should a resetting of hook be necessary, loosen screw (1) and turn
eccentric hook barrel (2) (Fig. 2).
Fig. 2