![Strobel 325-40D-TP Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/strobel/325-40d-tp/325-40d-tp_mechanics-instructions_1384781011.webp)
7
MA_325-40D-TP_A9_181015_en
2.5
Plunger highest position to the needle
2 mm before centre plunger
Brief setting instruction
Plunger stops to the needle
2 mm after centre plunger
Transport length lower feed
2 - 10 mm
Transport length
upper feed
4 - 12 mm
Feed plate lift
max.5 mm
Feed plate rises
Needle point
18 mm
before centre plunger
Play between feed plate and
14,5 mm Machine must
Stitch plate
rotate without difficulty
Setting value of hook point
1.8
±
0.2 mm
to the needle eye
Distance of guide block in relation
2.5 ±0.5 mm
to plunger guide plate
Loop stroke
2.5 – 3 mm