background image

Figure 9

Wall girts

Door mullions

Door lintel

835mm

2250mm

Pop rivet the PA door
header flashing to the
door mullions (only for
2.7 and 3m high garages).

PA DOOR FRAME

2210mm

Notch the end
to suit the top
wall girt.

PA door

11mm diameter shaft

45mm

7mm diameter 

Figure 8

Figure 10

Under-lap

Lip

Under-lap
Lip

PA Door Flashing

Butt Hinge

Door Mullions

Wall Girt

Wall Girt

Door Frame

Door Frame

Wall Sheet Cut Line

PA Door
Angle Trimmer

1

3

2

Cap bottom of the 
header sheets with 
the PA Door Header 
Flashing provided.

PA Door Gable End 

Header Flashing

Gable 
Header 
Sheets

STANDING THE WALL

Standing the Wall Frame

Stand the completed wall frame in the footing holes 

(refer to Figure 11), and temporarily brace it. Make sure 

the wall is level and square.

Repeat the previous steps for the other side wall frame. 
Stand the two wall frames in the holes and brace them 
securely.

BUILDING THE FRAME

Figure 11

PERSONAL ACCESS DOOR

Содержание Gable Homesheds

Страница 1: ...ur Homeshed on the second page of your Council Copy form This view can be copied from Figure 1 on page two You must include the distances from the boundaries and existing buildings Before Starting Con...

Страница 2: ...2 801 9 135 3 045 9 555 G4 3 921 x 6 207 3 563 6 087 3 045 7 051 G5 3 921 x 7 731 3 563 7 611 2 537 8 404 G6 3 921 x 9 255 3 563 9 135 3 045 9 805 G7 5 445 x 6 207 5 087 6 087 3 045 2 568 7 933 G8 5...

Страница 3: ...5 500 450 900 C 375 450 375 550 375 450 375 550 375 450 375 600 5445 A 375 700 450 800 450 700 450 900 450 900 600 900 B 375 450 375 700 375 500 450 800 375 700 600 900 C 375 450 375 550 375 450 375 5...

Страница 4: ...girt column holes facing up Dig the column holes as specified in Figure 2 and Table 2 If you are pouring a concrete slab the slab must be a minimum of 100mm deep Refer to Figure 3 and Table 2 Use str...

Страница 5: ...ugh the top pre punched hole in the columns Note If a boxgutter is to be installed the top wall girt will be offset from the top of the column by 100mm Refer to the boxgutter assembly instructions Wal...

Страница 6: ...er flashing Alternatively if a PA Door header flashing is provided rivet the PA Door header flashing to the door mullions to flash the area above the door opening Gable End PA Door For Homesheds great...

Страница 7: ...t Wall Girt Door Frame Door Frame Wall Sheet Cut Line PA Door Angle Trimmer 1 3 2 Cap bottom of the header sheets with the PA Door Header Flashing provided PA Door Gable End Header Flashing Gable Head...

Страница 8: ...mm self drilling hex head screws through the ridge bracket and into each rafter as displayed in Figure 13 Bolt the eaves bracket to each end of the rafter frames with four M12x30mm high tensile flange...

Страница 9: ...rated in Figure 16 Span three wall girts between each bracket and fix with two 10x16mm self drilling screws through each flange as shown in Figure 16 REAR WALLS AND ROOF INSTALLATION Figure 16 Bolt th...

Страница 10: ...These sheds will also require side wall end bays to be braced at one end of the shed only Bracing is to be fixed as illustrated in Figure 20 Roof Sheets Fix the roof sheets starting from one end of th...

Страница 11: ...ap Front Corner PA Door Flashing PA Door Mullion PA Door Lintel Z Tophat Sliding Door Header Beam Sliding Door Flashing Roller Door Header Flashing 2 6 3 7 4 8 1 5 9 10 11 12 13 14 15 Screw the front...

Страница 12: ...lling the window according to the Building the Frame section of this installation guide The sheet s in the location of the window will need to be trimmed to accomodate the window allowing for the base...

Отзывы: