background image

HOMESHED WALLS

Bolt with one
M12x30mm
hex head bolt

Columns

Wall girts

Laying

Direction

5mm

Under-lap

lip

WALL SHEETS

5mm

10x16mm
self-drilling
screws

Ensure the under-lap lip is aligned with the edge of the wall girts

CONSTRUCTING THE WALLS

Please Note:

 Girts will be supplied un-punched for Homesheds with non-standard lengths or non-standard bay spacings. 

Please refer to Table 1 on page 2 of this installation guide for a list of standard Homeshed lengths and bay spacings.

Figure 5

Figure 4

Wall Girts

Similarly, in standard Homesheds the wall girts have 
been pre-punched at each wall girt/column connection. 

Place the wall girts across the columns and match the 
pre-punched holes. Refer to Figure 4.

Fasten the top girt to the column with a high-tensile 

12x30mm flanged purlin bolt through each hole. The 

top girt is fixed through the top pre-punched hole in the 
columns.

Note: If a boxgutter is to be installed, the top wall girt 
will be offset from the top of the column by 100mm. 

(Refer to the boxgutter assembly instructions).

Wall Sheeting

Ensure the framework is square and the diagonal 
measurements are equal. Start laying the sheeting from 
the back-end of the shed, to make sure the overlap seam 
is not visible from the front of the shed. Ensure the top 
edge of the wall sheets are aligned parallel with the top 
edge of the top wall girts as illustrated in Fiqure 5.

Pan fix the Stratco Superdek

®

 wall sheets with 10x16mm 

self drilling screws at every girt junction. The sheets are 

laid with the short rib overlapping. Before fastening all 

screws, run a string line from both ends of the wall panel 
through the centre of the girts to ensure all the screws 

will be fastened in line.

The top of each wall sheet must be 5mm below the top 

wall girt. This will prevent any rubbing between the wall 
and roof sheets.

Check the wall frame remains square as the wall sheets 
are fixed.

Содержание Gable Homesheds

Страница 1: ...ur Homeshed on the second page of your Council Copy form This view can be copied from Figure 1 on page two You must include the distances from the boundaries and existing buildings Before Starting Con...

Страница 2: ...2 801 9 135 3 045 9 555 G4 3 921 x 6 207 3 563 6 087 3 045 7 051 G5 3 921 x 7 731 3 563 7 611 2 537 8 404 G6 3 921 x 9 255 3 563 9 135 3 045 9 805 G7 5 445 x 6 207 5 087 6 087 3 045 2 568 7 933 G8 5...

Страница 3: ...5 500 450 900 C 375 450 375 550 375 450 375 550 375 450 375 600 5445 A 375 700 450 800 450 700 450 900 450 900 600 900 B 375 450 375 700 375 500 450 800 375 700 600 900 C 375 450 375 550 375 450 375 5...

Страница 4: ...girt column holes facing up Dig the column holes as specified in Figure 2 and Table 2 If you are pouring a concrete slab the slab must be a minimum of 100mm deep Refer to Figure 3 and Table 2 Use str...

Страница 5: ...ugh the top pre punched hole in the columns Note If a boxgutter is to be installed the top wall girt will be offset from the top of the column by 100mm Refer to the boxgutter assembly instructions Wal...

Страница 6: ...er flashing Alternatively if a PA Door header flashing is provided rivet the PA Door header flashing to the door mullions to flash the area above the door opening Gable End PA Door For Homesheds great...

Страница 7: ...t Wall Girt Door Frame Door Frame Wall Sheet Cut Line PA Door Angle Trimmer 1 3 2 Cap bottom of the header sheets with the PA Door Header Flashing provided PA Door Gable End Header Flashing Gable Head...

Страница 8: ...mm self drilling hex head screws through the ridge bracket and into each rafter as displayed in Figure 13 Bolt the eaves bracket to each end of the rafter frames with four M12x30mm high tensile flange...

Страница 9: ...rated in Figure 16 Span three wall girts between each bracket and fix with two 10x16mm self drilling screws through each flange as shown in Figure 16 REAR WALLS AND ROOF INSTALLATION Figure 16 Bolt th...

Страница 10: ...These sheds will also require side wall end bays to be braced at one end of the shed only Bracing is to be fixed as illustrated in Figure 20 Roof Sheets Fix the roof sheets starting from one end of th...

Страница 11: ...ap Front Corner PA Door Flashing PA Door Mullion PA Door Lintel Z Tophat Sliding Door Header Beam Sliding Door Flashing Roller Door Header Flashing 2 6 3 7 4 8 1 5 9 10 11 12 13 14 15 Screw the front...

Страница 12: ...lling the window according to the Building the Frame section of this installation guide The sheet s in the location of the window will need to be trimmed to accomodate the window allowing for the base...

Отзывы: