background image

Corrugated

roof sheet

Valley

Turn up the

valley flute

Spanner

ROOF SHEETS

Figure 18

DOWNPIPES

WALL BRACING

Slide the small end of one downpipe into the big end of 
the other. Rivet the downpipe at the back, then use a 
hacksaw to cut to the desired length. 

Fix the downpipe to the existing outlet using rivets, then 
use downpipe straps to fix the downpipe against the wall 
using 10x16mm self drilling screws.

For Homesheds 5.4m or wider located in a N3 (W41) wind 

speed category, a strap brace must be fixed around the 
centre portal frames as illustrated in Figure 19. 

End bay brace

Fix with three

14x20mm self tapping

screws on each end

END BAY BRACING

Figure 20

Strap brace

30x0.8mm

Fix with three

10x16mm Self

drilling screws

STRAP BRACE

Central protal

frame

Figure 19

These sheds will also require side wall end bays to be 

braced, at one end of the shed only. Bracing is to be 
fixed as illustrated in Figure 20.

Roof Sheets

Fix the roof sheets, starting from one end of the 
Homeshed. Sheets should be laid into the prevailing wind.

Crest fix the sheets with 12x35mm self drilling screws  
or M6x50 timber/steel screws with neoprene washers. 
Use five screws per sheet at each end support, and 
three screws per sheet at each internal support.

Ensure the first sheet is square with the frame and 
that the roof sheets overhang into the gutter by 
approximately 50mm.

Turn the valley flute of every corrugated roof sheet 

upwards as illustrated in Figure 18. This will aid in 
water proofing the Homeshed.

If it is necessary to walk over roof sheets, ensure that 
you walk over the purlins to avoid any damage. Wear 
flat, rubber soled shoes and walk flat footed, spreading 
your weight over as many corrugations as possible.

REAR WALLS AND ROOF INSTALLATION

Содержание Gable Homesheds

Страница 1: ...ur Homeshed on the second page of your Council Copy form This view can be copied from Figure 1 on page two You must include the distances from the boundaries and existing buildings Before Starting Con...

Страница 2: ...2 801 9 135 3 045 9 555 G4 3 921 x 6 207 3 563 6 087 3 045 7 051 G5 3 921 x 7 731 3 563 7 611 2 537 8 404 G6 3 921 x 9 255 3 563 9 135 3 045 9 805 G7 5 445 x 6 207 5 087 6 087 3 045 2 568 7 933 G8 5...

Страница 3: ...5 500 450 900 C 375 450 375 550 375 450 375 550 375 450 375 600 5445 A 375 700 450 800 450 700 450 900 450 900 600 900 B 375 450 375 700 375 500 450 800 375 700 600 900 C 375 450 375 550 375 450 375 5...

Страница 4: ...girt column holes facing up Dig the column holes as specified in Figure 2 and Table 2 If you are pouring a concrete slab the slab must be a minimum of 100mm deep Refer to Figure 3 and Table 2 Use str...

Страница 5: ...ugh the top pre punched hole in the columns Note If a boxgutter is to be installed the top wall girt will be offset from the top of the column by 100mm Refer to the boxgutter assembly instructions Wal...

Страница 6: ...er flashing Alternatively if a PA Door header flashing is provided rivet the PA Door header flashing to the door mullions to flash the area above the door opening Gable End PA Door For Homesheds great...

Страница 7: ...t Wall Girt Door Frame Door Frame Wall Sheet Cut Line PA Door Angle Trimmer 1 3 2 Cap bottom of the header sheets with the PA Door Header Flashing provided PA Door Gable End Header Flashing Gable Head...

Страница 8: ...mm self drilling hex head screws through the ridge bracket and into each rafter as displayed in Figure 13 Bolt the eaves bracket to each end of the rafter frames with four M12x30mm high tensile flange...

Страница 9: ...rated in Figure 16 Span three wall girts between each bracket and fix with two 10x16mm self drilling screws through each flange as shown in Figure 16 REAR WALLS AND ROOF INSTALLATION Figure 16 Bolt th...

Страница 10: ...These sheds will also require side wall end bays to be braced at one end of the shed only Bracing is to be fixed as illustrated in Figure 20 Roof Sheets Fix the roof sheets starting from one end of th...

Страница 11: ...ap Front Corner PA Door Flashing PA Door Mullion PA Door Lintel Z Tophat Sliding Door Header Beam Sliding Door Flashing Roller Door Header Flashing 2 6 3 7 4 8 1 5 9 10 11 12 13 14 15 Screw the front...

Страница 12: ...lling the window according to the Building the Frame section of this installation guide The sheet s in the location of the window will need to be trimmed to accomodate the window allowing for the base...

Отзывы: