A-19
Reference
Applications Manual
10MAY01
X, Y, and Z offset calibration
1. Follow standard steps for Tip offset calibration.
a. Start FDM Status.
b. Click the Calibration button.
·
Specify the properties of the modeler in the
Configure Modeler
window. This
is much like the configuration window in Insight.
Specify the: model & support material types, model & tip sizes, and
the slice height
c. Click to confirm the modeler configuration parameters. These parameters
will determine the values used to build the calibration box used to set the tip
offset values.
d. The
Calibration
window is displayed.
e. Choose
Cal boxes and Tip offsets
as the type of
Download data
. For tip-offset
calibration, you will want to download the current offsets and a calibration
box.
f. Click the Download button to build an initial calibration box using the
current modeler configuration and offset values.
g. The FDM Pause light will start to blink. Press the Pause button to initiate the
XYZ homing procedure. When the Pause light starts to blink again,
the extrusion head will be in the front-left corner. Lower the tip so that
it is touching the foam. Press the Pause light again to start building
the calibration box.
h. Verify the results, and modify the X and Y offsets to position the support
material directly on top of the model material. Do this by clicking the
+/- X and +/- Y buttons to shift the location of the support material
bead. You can also enter numeric values for the X and Y offset incre
ments.
i.
Repeat steps 7 through 9 as necessary until the support material is centered
on the model material.
j.
After completing the X and Y offset calibration, peel away the support mate-
rial layer from the final calibration box. Measure the Z-thickness of
thesupport material bead using a caliper or micrometer. The thickness
should be 0.010 inches for the T16 tip.
k. If the support bead is too tall or too short, use the +Z and -Z buttons to
change the Z offset.
l.
After changing the Z offset, build a new calibration box by clicking the Down-
load button.
m. Repeat steps 11 through 13 until the support-material bead is the correct
height.
Use these additional steps to fine tune the calibration:
1. Close the Calibration window.
2. Open
Set Preferences
.
a.
Check
Allow Stripped File Download
.
b.
Close the Set Preferences window.
3. In the FDM Status main window, open the
Pack and Download
window.
Содержание FDM 2000
Страница 1: ...Introduction FDM 2000 3000 8000 Release 2 0 Stratasys Document no 105208 0001 Rev B...
Страница 12: ...Contents F2 3 8000 i 10 MAY 01 Release 2 0 FDM Manual 2000 3000 8000 Stratasys Document No 105207 0001 Rev B...
Страница 17: ...Contents FDM 2000 3000 8000 Manual 10 MAY 01 F2 3 8000 vi...
Страница 98: ...U 1 Reference UtilitiesManual 10MAY01 Utilities Manual Release 6 0 Stratasys Document No 105212 0001 Rev B...
Страница 104: ...Reference N 1 Notes 10MAY01 Technical Notes Release 5 0 Technical Notes Stratasys Document no 105214 0001 Rev B...
Страница 105: ...Reference N 2 Notes 10MAY01 Release 1 0 October 1997 5 0 May 2001...
Страница 123: ...Reference 10MAY01 F2 3 8000 43 Reference FDM 2000 3000 8000 Release 2 0 Stratasys Document no 105210 0001 Rev B...
Страница 131: ...G 1 Reference Glossary 10MAY01 Release 4 0 Glossary Stratasys Document no 105213 0001 Rev B...
Страница 141: ...Reference Appendix M1 M1 1 10MAY01 Appendix M1 Materials Release 5 0 StratasysDocumentno 105215 0001 Rev B...