Reference
®
10MAY01
F2/3/8000-49
Keypad Display Messages
Key pad messages display information about the FDM.
PD Time Fault
The PD Time Fault message appears when a PD time exceeds five con-
tinuous seconds.
XY Time Fault
The XY Time Fault message appears when there is uninterrupted head
movement for five minutes.
Torque Limit
The Torque Limit message appears when the active torque on the
motor exceeds the preset limit.
Filament Out
This message appears if there is no filament loaded in the FDM. It
also appears if neither filament sensor detects filament for 30
seconds
while there is XY head movement.
Load Time Fault
This message appears if the operator tries to load filament for 2
consecutive minutes. It indicates the feed to the liquefiers has
been shut off.
NV Memory Error
This message indicates one of the values stored in the keypad is
outside the acceptable range. The user should check the keypad
values.
Low Temp Set
This
message indicates that the support watlow has lowered to it’s “safe
temperature.
Pressing “Enter” clears any alarm messages.
The “% FLOW” setting has a direct relationship effect on the gain
numbers during modeling.
Содержание FDM 2000
Страница 1: ...Introduction FDM 2000 3000 8000 Release 2 0 Stratasys Document no 105208 0001 Rev B...
Страница 12: ...Contents F2 3 8000 i 10 MAY 01 Release 2 0 FDM Manual 2000 3000 8000 Stratasys Document No 105207 0001 Rev B...
Страница 17: ...Contents FDM 2000 3000 8000 Manual 10 MAY 01 F2 3 8000 vi...
Страница 98: ...U 1 Reference UtilitiesManual 10MAY01 Utilities Manual Release 6 0 Stratasys Document No 105212 0001 Rev B...
Страница 104: ...Reference N 1 Notes 10MAY01 Technical Notes Release 5 0 Technical Notes Stratasys Document no 105214 0001 Rev B...
Страница 105: ...Reference N 2 Notes 10MAY01 Release 1 0 October 1997 5 0 May 2001...
Страница 123: ...Reference 10MAY01 F2 3 8000 43 Reference FDM 2000 3000 8000 Release 2 0 Stratasys Document no 105210 0001 Rev B...
Страница 131: ...G 1 Reference Glossary 10MAY01 Release 4 0 Glossary Stratasys Document no 105213 0001 Rev B...
Страница 141: ...Reference Appendix M1 M1 1 10MAY01 Appendix M1 Materials Release 5 0 StratasysDocumentno 105215 0001 Rev B...