5.2 Maintenance
scheme
Component to check
Often
Every
month
Every 3
months
First 6
months
Every
year
Every 3
years
Check quantity of oil in the tank
(paragraph 5.1.1)
X
Check/clean oil filter with measur-
ing pin (paragraph 5.1.2)
X
Replace return filter (paragraph
5.1.3)
X
X
Replace suction filter (paragraph
5.1.4)
X
Check the movable parts of the
barn cleaning installation.
X
Oil
change
X
5.3 Irregularities
PROBLEM
POSSIBLE REASON
REMEDY
Electric motor of the hydraulic
pump stops (installations with
Start-O-Matic)
There is a leakage in the hydraulic
systems causing loss of pressure
(pressostate has been active)
Find the leakage and repair. Refill
hydraulic oil. It might be necces-
sary to call the STRANGKO fitter.
Cylinders change between for-
ward and backward movement
with short intervals.
The switch valve is out of order, or
adjusted incorrectly.