GIGANT - GIGANT - GIANT
trangko
S
Nr. 7000
201
_________________________________________________________________
941212
__________________________________________________________________________________________________________________________________________________________________________________________________________________
______
BRUGERVEJLEDNING - BEDIENUNGSANLEITUNG - USER’S MANUAL
7000201a
19
If the installation is equipped with a separate hydraulic pump for the cylinders in the gutters the installa-
tion has to be stopped by activating the stop buttons as follows:
a. Stop the scrapers in the gutters/side canals
b. Stop the scraper in the main canal.
4.2.2
Start - o - matic operation
Adjust the timer to the wanted operation time, and thus the installation will be stopped when the time has
passed.
4.2.3 In
general
The installation can be stopped by means of the main switch in case of irregularities. E.g. the installation
should be stopped immediately if the scrapers in the main canal by accident should stop.
This will facilitate possible later repair work.
If there is a loss of pressure because of leakage or similar, and the installation is equipped
with start - o - matic a pressure switch will stop the motor. This is to ensure that the instal-
lation will not go empty and thus damage the pump and the motor.
5.
MAINTENANCE
Cleaner, used filters an used hydraulic oil should be removed according to existing regulations.
The STRANGKO Barn Cleaning Installation is simple, sturdy and reliable and demands very little care.
However, you have to obey to the following plan in order to ensure a long lifetime for your installation.
Before starting the installation for the first time - or after a longer period of not being used - all parts have
to be oiled according to the following instructions:
5.1 Pump
station
5.1.1
Controlling the oil level
The oil level should be controlled once a week.
1. Remove the air filter with the measuring pin.
2. The oil level in the tank can be seen at the oil pin.
3. If the oil level is to low, put on more hydraulic oil, type VG-32-HM (ISO).
5.1.2
Cleaning the air filter
The air filter with measuring pin should be cleaned every 3 month.
1. Unscrew the air filter with the measuring pin.
2. Move the filter up and down several times in diesel oil.
3. Shake the air filter with the measuring pin several times.
4. Screw in the air filter.
5.1.3
Replacing the return filters
There is a return filter at the pump station. It should be replaced for the first time within 6 months. After
that replace the return filters once a year.