GIGANT - GIGANT - GIANT
trangko
S
Nr. 7000
201
_________________________________________________________________
941212
__________________________________________________________________________________________________________________________________________________________________________________________________________________
______
BRUGERVEJLEDNING - BEDIENUNGSANLEITUNG - USER’S MANUAL
7000201a
16
5.3 Betriebsstörungen
PROBLEM
MÖGLICHE URSACHE
BESEITIGUNG
El-Motor für die Hydraulikpumpe
setzt aus (bei Anlagen mit Start-O-
Matic)
Es gibt ein Leck in der hydrauli-
schen Anlage, das Druckverlust
verursacht. (Pressostat-
Abschaltung)
Das Leck finden und ausbessern
und mit Hydrauliköl nachfüllen.
Eventuell den STRANGKO Mon-
teur rufen.
Zylinder wechseln mit kurzen Zwi-
schenräumen zwischen vor- und
rückwärts Bewegung.
Der Druckumschalter is außer
Betrieb, verschmutzt oder falsch
eingestellt.
Den STRANGKO Monteur rufen.
Schmierschema und Spezifikationen finden Sie in den Abschnitten 6 und 7.
ENGLISH USER’S MANUAL
PREFACE
In order to be sure that you use your GIANT Barn Cleaning System optimally, it is important, that you
read this User's Manual carefully. By following the advice given concerning safety, use and maintenance
you will experience that your new installation is a stable and reliable help in the daily life and for the next
many years to come.
SAFETY
This safety- and warning symbol indicates that important safety regulations and directions for avoiding
accidents are mentioned in the paragraph.
1.
SAFETY REGULATIONS
Never
clean, grease, maintain or repair the barn cleaning installation unless the main
switch has been turned off and locked.
Never
try to take out blocked manure or other items from the scrapers, unless the main switch has been
turned off.
Never
enter the cleaning canal unless the main switch has been turned off and locked.
Never
throw hard or big items into the gutters or canals.
Always
shut the cleaning shutters, when the installation is out of use.
The canals should
always
be solidly roofed and shielded.
Never
use the elevator without a shield.
When mounting new scrapers in open canals or gutters it must be ensured that these have the correct
lenght compared to the width of the gutter.