Multisport
452
ZI de Bel Air 44850 LE CELLIER FRANCE [email protected] Tél. +33 (0)2 40 25 46 90
IASC24_A - Installation SC24.docx
Page 5
YBJ30
1
2
3
4
T
2
4
1
3
452M
T
S
Q
P
YBJ30/YBJ35
YBJ35
2
4
1
3
Q
T
S
P
Control cables wall junction box (Cable transmission model or radio controlled
model supplied with the cable kit option)
Caution: the display units must not be connected to mains before installation has been fully completed.
The transmission cable supplied is a telephone cable: type 2 pairs 6/10
ths
.
Connect the control cables (Q) on the connectors (T) of the display units
making sure that the colour code is followed (Please note – RS485: Rx+
and Rx- must be connected on a twisted pair).
Fix the cables onto the wall or onto the support frames.
Put the control cable into place making sure that it does not run along side the 100-240V mains cables.
Connect the end wires into the junction box YBJ35 or YBJ30 (main scoreboard 452M), making sure that the colour code is
followed. The cables must be wired in parallel in the wall junction box.
Control cable (Q): (1) = GND = blue wire / (2) = Rx+ = white wire / (3) = Rx- = grey wire / (4) = +24V = transparent wire
End of the installation
Try out the scoreboard operating functions (see operating functions).
S
T