INSTALLATION
Fixing Bracket Advice
Dealing with sides, cross-rails and
back-panels in the cabinet.
Depending on the cabinets, the work-
top thickness and the hob positioning, it
is possible for the hob base and/or the
clamp brackets to interfere with parts of
the cabinet.
Cut away cabinet and use appropriate fix
-
ing brackets for your installation.
Note;
Attach the clamps and 4 x self tap-
ping screws in the fixing bracket locations
as shown in the diagram.
WORKTOP
30mm
HOB
SCREW
WORKTOP
HOB
SCREW
40mm
FIXING POINTS
FIXING POINTS
Connect to the electricity supply
(For Fixed Wiring only)
WARNING:
This appliance must be
earthed. Only connect to the electrical
mains terminal with the power switched
off. The electrical mains terminal is live.
Follow the terminal block connection
schematic.
Loose and inappropriate connections can
make the terminal overheat.
Ensure the cable clamp is fitted correctly
and securely.
A device must be provided in the electri-
cal installation which allows the appliance
to be disconnected from the mains at all
poles with a contact opening of at least
3mm.
We recommend that the appliance is con-
nected by a competent person who is a
member of a “Competent Person Scheme”
who will comply with the required local
regulations.
Connection should be made with a suit-
able cable.
Important:
Ensure that you route all
mains electrical cables well away from any
adjacent heat source, such as an oven or
grill.
Strip the wires & connect to the terminal
block as shown in the terminal block sche-
matic. Fit the cable clamp & secure with
the screw provided. Close the terminal
box, ensuring that the cover is engaged
on the locking tabs.
The cable clamp, screw and terminal block
cover are supplied in the instructions/fit
-
tings bag
Caution:
The terminal block is already
adjusted to accept the cables and un-
screwing is not required. The terminal
block screws & clamps can be damaged