Installation Instructions
This appliance is adjusted for NATURAL GAS at 20mbar
ONLY.
The hob is suitable for conversion to Liquid Petroleum Gas
(BUTANE (G30) at 28-30 mbar and PROPANE (G31) at
37 mbar by the following procedure using the kit supplied.
If you require a replacement kit, please contact our spares
department on 0870 458 9695 and give the model number
from the databadge on your appliance.
Replace the injectors with the corresponding injector from
the table on page below.
First remove the burner caps and rings and with a socket
spanner “B”, unscrew injector “A” (see fig. 7).
The adjustment of the reduced rate position is as follows
(fig. 8):
light the burner and turn the knob fully anti-clockwise to
reduced rate position.
Remove the knob “M” which is simply inserted onto tap
stem.
Insert a small screwdriver “D” into the top shaft “C” and
turn the bypass screw left or right until flame of the
burner is correctly regulated at the low position.
Make sure that when turning quickly from “Full on”
position to reduced rate position that the burner does not
extinguish.
FIG. 8
FIG. 7
Injector Replacement Table
B
URNER
D
ESCRIPTION
G
AS
T
YPE
N
ORMAL
P
RESSURE
N
ORMAL
R
ATE
I
NJECTOR
D
IAMETER
N
OMINAL
H
EAT
I
NPUT
(W)
mbar
g/h
l/h
1/100mm
min
max
Wok
Butane
Propane
Nat Gas
28 - 30
37
20
244
239
333
91zE
91zE
145zE
1450
1450
1450
3350
3350
3500
Rapid
(large)
Butane
Propane
Nat Gas
28 - 30
37
20
182
179
238
78zE
78zE
120zA
800
800
800
2500
2500
2500
Semi Rapid
(medium)
Butane
Propane
Nat Gas
28 - 30
37
20
127
125
167
68zE
(2)
68zE
(2)
98zA
(3)
500
500
500
1750
(1)
1750
(1)
1750
(1)
Auxiliary
(small)
Butane
Propane
Nat Gas
28 - 30
37
20
73
71
95
50zE
50zE
78zA
400
400
400
1000
1000
1000
(1)
1400 W for models with Griddle plate
(2)
60zE for the models with Griddle plate
(3)
85zA for the models with Griddle plate