background image

Installation

T

ECHNICAL

 

INFORMATION

The  installation,  the  adjustments,  conversions  and

maintenance listed in this part must only be carried out by

qualified persons.

The  safety  and  automatic  adjustment  devices  of  the

appliance  may  only  be  modified  by  an  authorised  Belling

service agent. 

The  installation  of  this  gas  hob  must  comply  with  the     

standards in force.

This appliance is not connected to a flue for discharge of

the combustion products; therefore, it must be connected

in compliance with the above mentioned installation rules.

Particular attention must be paid to the instructions given

below for ventilation and aeration.

L

OCATION

The  cooker  may  be  located  in  a  kitchen,  kitchen/diner  or  a

bed-sitting  room,  but  not  in  a  room  containing  a  bath  or

shower. The hob must not be installed in a bed-sitting room

of less than 20 m

3

.

LPG models shall not be installed in a room or internal space

below ground level, e.g. in a basement.

P

ROVISION

 

FOR

 

VENTILATION

The room containing the cooker should have an air supply in

accordance with BS 5440: Part 2.

The room must have an opening window or equivalent; some

rooms may also require a permanent vent. If the room has a

volume between 5 and 10 m

3

, it will require an air vent of 50

cm

2

effective area unless it has a door which opens directly to

outside. If the room has a volume of less than 5 m

3

, it will

require an air vent of 100 cm

2

effective area (fig. 1). If there

are other fuel burning appliances in the same room, BS 5440:

Part  2  should  be  consulted  to  determine  air  vent

requirements.

NOTE: 

the  use  of  a  gas  cooking  appliance  results  in  the

production  of  heat  and  moisture  in  the  room  in  which  it  is

installed.  Always  ensure  that  the  kitchen  is  well  ventilated;

keep  natural  ventilation  holes  open  or  install  a  mechanical

ventilation device (fig. 2).

In particular, when using the grill or more than one hotplate

burner,  open  a  window  if  a  mechanical  ventilation  device  is

not operating (fig. 3).

(*) Air inlet - minimum section: 100 cm

2

Make  sure  that  you

have  removed  al  the

packaging  informa-

tion before you begin

installation.  Any pro-

tective  films  /  plas-

tics 

should 

be

removed  before  the

appliance is used. 

FIG. 1

FIG. 2

FIG. 3

Packaging  materials

are  hazardous  to

small 

children.

Please  dispose  of  it

carefully.

Содержание S5-G700E

Страница 1: ...S7 G900C S7 G1100C Handbook...

Страница 2: ...Contents If you smell gas Do not try to light any appliance Do not touch any electrical switch Call the Gas Emergency Helpline at TRANSCO on 0800 111999 COD 04059ST 17 10 2007...

Страница 3: ...ommend that you wear protective gloves when installing and moving this appliance This will prevent any injury Our policy is one of constant development and improvement Strict accuracy of illustrations...

Страница 4: ...i Rapid medium 1 75 Auxiliary small 1 0 Hob Dimensions Width 860mm Depth 500mm Height to top of pansupports 60mm Cut out required WxD 833mm x 473mm Hob Aesthetics 5 burners Automatic ignition Cast Iro...

Страница 5: ...Rapid medium 1 4 1 75 Hob Dimensions Width 1100mm Depth 370mm Height to top of pansupports 80mm Cut out required WxD 1060mm x 345mm Hob Aesthetics 4 burners Automatic ignition Cast Iron pansupports g...

Страница 6: ...en gloves is recommended when during use 5 Do not allow children to operate or play with any part of the appliance 6 Do not use unstable pans and position handle away from the edge of the hob The use...

Страница 7: ...duced rate position Always put a lid on the pan USING THE GRIDDLE When using the griddle make sure that it is placed over the burners as shown in the illustration at the front of this handbook Do not...

Страница 8: ...m which is not noticeable in normal use then after wiping with a cloth wrung out in clear water dry with a soft clean cloth Use a nylon brush to remove any cleaning materials water or dirt from the ho...

Страница 9: ...heat and steam The hob has a special seal which prevents liquid from entering the cabinet Follow these instructions in order to correctly apply this seal detach the seals from their backing checking...

Страница 10: ...ordance with BS 5440 Part 2 The room must have an opening window or equivalent some rooms may also require a permanent vent If the room has a volume between 5 and 10 m3 it will require an air vent of...

Страница 11: ...CTION This appliance must be connected by a competent person using fixed wiring via a double pole switched fused spur outlet with a contact separation of at least 3mm in all poles We recommend that th...

Страница 12: ...ert a small screwdriver D into the top shaft C and turn the bypass screw left or right until flame of the burner is correctly regulated at the low position Make sure that when turning quickly from Ful...

Страница 13: ...it yellow BURNER FAILING TO IGNITE Check that the power is turned on or that the fuse has not blown Make sure that the ignitor isn t coated with food spillage SPARK BUT NO GAS Make sure the gas is tu...

Страница 14: ...rial number in the space below Where are my model and serial numbers Freestanding HL appliances base of storage drawer Freestanding appliances front frame near oven cavity Built in oven front frame ne...

Страница 15: ......

Страница 16: ...Lane Prescot Merseyside L35 2XW Tel Customer Care 0871 222 2502 Trade Support 0871 222 2625 Customer Support Line 0871 222 2635 Fax 0871 222 2645 Stoves is a member of Glen Dimplex Home Appliances 8 2...

Отзывы: