Programming : Set the Penalty Time for Invalid Code
When in Code Entry mode, if
after twenty key presses a valid
code has not been entered, the
keypad will be disabled for a
pre-set period of time. This
feature is intended to deter any
attempt to gain unauthorised
access by guessing the format
of a valid code.
To set the Invalid Code Penalty
Time, ‘log on to Programming Mode’,
then enter 7 to select the Invalid Code
Penalty Time function.
Listen for the ‘accept bleep’.
Then enter a two-digit number to
set the duration of the Penalty
Time in seconds (01-99)
Listen for the ‘accept bleep’.
Enter 0 to Log Off
Listen for the ‘accept bleep’
To reset Invalid
Penalty Time when in
Programming Mode.
(LED is
flashing )
Enter
Enter Penalty Time in
seconds
Enter
Start new
command sequence
Enter option
to
LOG OFF
NOW ?
Enter
YES
NO
LED flashing
changes to
when you log off