Programming : Change or Reset the Engineers Code
If the Engineers Code is known then log on to enter Programming Mode, and enter 4 to select a new code.
Alternatively, if the engineer’s code is not known, power down the keypad for a period of not less than three
seconds. Power up the keypad and within a two minute period enter the Engineer reset code.
Do not enter any other digits before entering this code. The keypad’s LED will then begin flashing to indicate
that the keypad is in programming mode. Enter 4 to select a new engineer’s code;
If code is not known
‘Power Down’
then ‘Power Up’
Enter
725
to log on
Enter
Engineer’s Code
#
To select new
Engineer’s Code
Enter
Enter
Enter new 6 digit
Engineers Code
Start new
command sequence
Enter
to
LOG OFF?
Enter
NO
YES