18
Gültig seit/Valid from/Valide: 09.10.2019
Combustion mode
ECO
– the Air flap is partially shut (reduced combustion)
o
Use this setting if you want the fire to burn at a lower intensity, for instance when
the heating area is already at the right temperature.
SMART
– the Air flap is controlled automatically by the configured program
o
Use this setting if you don’t want reduced or high-intensity combustion.
TURBO
– the Air flap is nearly completely open (more intense combustion)
o
Use this setting if you want to increase the furnace’s heat output.
o
TURBO mode is automatically used by the regulator whenever a new fire is started in
a cold furnace (the fuel needs more air to start the fire). The mode then switches to
the previously used setting after the next stoking.
Course of combustion (Burning cycle)
A graphical circular display shows the current combustion
stage.
1 - stand-by mode (grey) – (flap = 0%)
1-2 - starting the fire (green - yellow) – (fl. = 40-100%)
2-3 - burning time (red) – (flap = 30-100%)
3-4 - cooling down (yellow) – (flap = 30-100%)
4-1 - new loading (green) – (flap = 15%)
Flue gas temperature
The current temperature of the flue gas in the furnace.
Air flap position
The current position of the Air flap.
100 % = the shutter is completely open
0 % = the shutter is completely closed
Burning time
The current burning time (time elapsed since the start of regulation until transfer to standby
mode).
Combustion history and max. temperature graph
The graph displays the history of the previous 10 combustion cycles.
For each of these, the graph shows:
The maximum achieved flue gas temperature during combustion
Whether less (yellow column), optimal (green column) or more (red column) fuel was
stoked
Stoking statistics
Stoking figures for the last day (D), week (W), month (M) and total since the last reset of
statistics (S).
The statistics can be reset in the user settings.
Содержание SIC 700 S
Страница 1: ...Gültig seit Valid from Valide 09 10 2019 User Manual AUTOMATIC BURNING REGULATOR SIC 700 SMART EN ...
Страница 13: ...13 Gültig seit Valid from Valide 09 10 2019 2 4 2 Door switch assembly ...
Страница 14: ...14 Gültig seit Valid from Valide 09 10 2019 2 4 3 Assembly of the central unit ...
Страница 15: ...15 Gültig seit Valid from Valide 09 10 2019 2 4 4 Servomotor assembly ...
Страница 16: ...16 Gültig seit Valid from Valide 09 10 2019 2 4 5 Assembly of LED display ...