Getting Started - RAID Array 410 for HP-UX
2–4
EK–SMRA3–IG. C01
•
Cache condition should be GOOD
If the Cache condition is BAD then call your sales person for unit service or
replacement of the Cache module.
•
Battery condition should be GOOD
If the battery condition is LOW, allow the battery to charge with the subsystem power
on for at least 6 hours. The battery must be fully charged to protect the data in the
Write Back Cache. If the battery condition is still listed as LOW after 6 hours of
charging, call your sales person for unit service or replacement of the batteries.
Set the controller SCSI target number:
SWXRC> SET THIS_CONTROLLER ID=0
SWXRC> SET THIS_CONTROLLER PERFERRED_ID=0
Enter the following command to copy parameters to the other controller – the one the
terminal is not connected to:
SWXRC> SET FAILOVER COPY=THIS_CONTROLLER
SWXRC> RESTART OTHER_CONTROLLER
SWXRC> RESTART THIS CONTROLLER
Enter the following commands to verify the preceding parameters were set:
SWXRC> SHOW THIS_CONTROLLER FULL
SWXRC> SHOW OTHER_CONTROLLER FULL
2.5
Remove Default Logical Unit
The subsystem was configured at the factory with a single drive (DISK100) as a logical unit
(D0) available to the host. In order to configure the array, it is necessary to remove the
logical unit. Use the following CLI command to do so.
SWXRC> DELETE D0
NOTE
The last character in the command is a zero, not the letter “oh”.
Содержание RAID Array 410
Страница 25: ...Getting Started RAID Array 410 for HP UX 2 12 EK SMRA3 IG C01 Date__________________ LUN Uses...
Страница 41: ...Getting Started RAID Array for HP UX A 2 EK SMRA3 IG C01 Date_____________ LUN Uses...
Страница 43: ...Getting Started RAID Array for HP UX A 4 EK SMRA3 IG C01 Date_____________ LUN Uses...
Страница 45: ...Getting Started RAID Array for HP UX A 6 EK SMRA3 IG C01 Date_____________ LUN Uses...
Страница 47: ...Getting Started RAID Array for HP UX A 8 EK SMRA3 IG C01 Date_____________ LUN Uses...