- 29 -
MAINTENANCE
RP850G / RP850D
MAINTENANCE WORK (Honda Engine)
Attention:
Only the maintenance work that has to be
performed daily is included in this operating manual.
Please refer to the engine operating manual and to the
maintenance instructions and intervals listed therein.
Filling up with fuel
Danger:
- Fill fuel tank only when engine is switched
OFF.
- No naked flames.
- No smoking.
- NEVER fill fuel tank in enclosed areas.
To check fuel level:
1. Clean the area around the fuel filling socket.
2. Open the cap.
3. Check the fuel level visually.
4. If necessary, fill up with fuel.
(unleaded automotive gasoline)
Checking the engine oil level
1. Park the machine horizontally.
2. Clean the area around the oil filler cap.
3. Open the oil filler cap.
4. Check the oil level.
5. Refill up to the edge of the oil filler cap if
necessary.
6. Check the seal on the dipstick and replace if
necessary.
7. Close the oil filler cap.
8. Allow the engine to run for approximately 1
minute and check oil level again with engine
switched off.
Cleaning the air filter element
Attention:
-
NEVER run the engine without the air cleaner.
Rapid engine wear will result.
-
DO NOT allow dust to enter the carburetor.
1. Remove the filter cover (1).
2. Take out the filter element (2 & 3).
3. Check the filter element, replace if damaged.
For slight clogging:
1. Clean the filter element (2) by tapping lightly.
2. Blow it from inside to outside with dry,
compressed air.
For heavy clogging:
1. Wash the filter element (3) in a non-flammable
cleaning solution and allow to dry thoroughly.