background image

Page 22

Due to continuous product research and development,
the information contained herein is subject to change without notice.

www.stoddart.com.au
www.stoddart.co.nz

Содержание CR.GC1.L.RC.L

Страница 1: ...R GC1 L RC R CR GC1 L RCL R CR GC1 L RCL R CR GC1 S RC L CR GC1 S RC R CR GC1 S RCL R CR GC1 S RCL R CR GC2 L RC CR GC2 L RCL CR GC2 S RC CR GC2 S RCL GLASS CHILLER REMOTE SINGLE DOUBLE DOOR SPECIFICA...

Страница 2: ...Page Intentionally Left Blank Page 1 Due to continuous product research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz...

Страница 3: ...Liquid Line Isolation Valves Refrigeration Lines Condenser Unit Remote Unit Leak Testing Diagram Climate Classes Electrical Connection 10 Plumbing Connections 10 Specification Technical Specification...

Страница 4: ...s not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction con...

Страница 5: ...g The manufacturer declines any liability for damages to persons and or things due to an improper wrong and or unreasonable use of the machine Only specifically trained qualified Technicians Stoddart...

Страница 6: ...d GC Glass Chiller 1 2 1 door 2 door L S Lift of lid Sliding Lid RC Right Hand Remote Service Compartment RCL Left Hand Remote Service Compartment L R Left Right hand hinged door Control Panel Install...

Страница 7: ...nit using a clean cloth dampened with warm soapy water When moving the unit ensure the cabinet is upright at all times When positioning the unit avoid direct sunlight warm drafts and heated areas for...

Страница 8: ...d valve Isolation valves suction line and liquid line are not sold or supplied with this product or by Stoddart For purchasing and installation of the solenoid contact a local refrigeration company En...

Страница 9: ...d fill with dry nitrogen to 1725kPa 250psi Close the pressure gauge and note the pressure reading Using a soapy solution check all the joints for leaks If leaks exist START If leaks exist If NO leaks...

Страница 10: ...3M1 Refrigerated Units in Commercial Kitchens would normally be climate class 4 CLIMATE CLASSES Test Room Climate Class Dry bulb temperature C Relative humidity Dew point C Water weightin dry air g k...

Страница 11: ...this manual require the power to the equipment to be turned o and isolated Turn the power OFF at the power point and unplug the power supply lead by the plug body If the power point is not readily acc...

Страница 12: ...TIONS Model CR GC1 L RC L CR GC1 L RC R CR GC1 L RCL L CR GC1 L RCL R CR GC1 S RC L CR GC1 S RC R CR GC1 S RCL L CR GC1 S RCL R Width 760mm Depth 668mm Height 880mm Voltage Frequency 240V 50Hz Power k...

Страница 13: ...ww stoddart com au www stoddart co nz Specification SPECIFICATIONS Model CR GC2 L RC CR GC2 L RCL CR GC2 S RC CR GC2 S RCL Width 1200mm Depth 668mm Height 880mm Voltage Frequency 240V 50Hz Power kW 0...

Страница 14: ...g the cabinet should not occur through the lid s Ensure the doors are CLOSED when not loading to maintain the temperature The cabinet should only be loaded with 14 x 14 and 14 x 17 glass baskets The r...

Страница 15: ...sed on The unit will maintain a default temperature after service for instant use the next day Switch OFF lights and door heaters to minimise power Ensure all doors are closed Defrost Cycle The system...

Страница 16: ...room temperature display KEY COMBINATIONS 1 Push and immediately release the SET key the display will show the set point value 2 Push and immediately release the SET key or wait 5 seconds to display...

Страница 17: ...is unit is NOT waterproof DO NOT hose DO NOT pour water directly onto the unit DO NOT immerse in water Stainless steel exhibits good resistance to corrosion however if not properly maintained stainles...

Страница 18: ...Do NOT let water pool check crevices and folds Doors Night Lids 1 Use a vacuum to remove dust and debris from all the ventilation panels 2 Do NOT use water or a hose to remove dust or debris Ventilati...

Страница 19: ...uit board Refrigeration circuit board s is hot T Replace Fix circuit board s Unit is too warm Ambient air entering the units O Door not closing sealing O Move unit exhaust fan O Open baffle Warm items...

Страница 20: ...tor retailer can contact their local metal recycling centre to collect the remaining cabinet shelves etc There may be special requirements or conditions Information on the disposal of refrigeration ap...

Страница 21: ...Page Intentionally Left Blank Page 20 Due to continuous product research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz...

Страница 22: ...Page 21 Due to continuous product research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz...

Страница 23: ...Page 22 Due to continuous product research and development the information contained herein is subject to change without notice www stoddart com au www stoddart co nz...

Страница 24: ...7694 New Zealand Sales Spare Parts Tel 0800 79 1954 Email sales stoddart co nz Email spares stoddart co nz Service Spare Parts Tel 0800 935 714 Email service stoddart co nz Email spares stoddart co nz...

Отзывы: