Loading Restrictions
• Air vents must NOT be covered
• Runners are only designed to hold baskets with one layer of glasses� Full baskets with glasses stacked on top of each other or other
objects in the baskets can bend and damage runners
• Runners should be adjusted to allow air space around all glasses for even refrigeration and efficient operation of the refrigerator
• An air space of at least 40mm should be maintained above, below and inbetween the shelves for air circulation
Operation
After Service - Information
• The refrigeration section should NOT be turned OFF after service
• Glasses can either be left in the unit or placed in night storage� Ensure all door(s) and lid(s) are closed/on
• The unit will maintain a default temperature after service for instant use the next day� Switch OFF lights and door heaters to minimise
power� Ensure all doors are closed
Defrost Cycle
• The system has an automatic defrost system which improves the energy efficiency of the unit and minimises temperature fluctuations
• After the unit is first switched ON the first defrost cycle will occur automatically after 3 hours� If the unit is NOT turned OFF, the unit will
defrost automatically 8 times per day or every 3 hours
• If air is not circulating properly a manual defrost cycle can be made� Normal automatic defrost cycles will still occur every 3 hours even
if a manual cycle has been run in between cycles� Check the electronic controller section for more information
• The defrost cycle terminates when the temperature of the evaporator coil rises to 6°C or after 30 minutes� Products will remain
refrigerated during defrost cycle if the doors remain closed
• For changing of defrost cycle settings, contact Stoddart or an approved service technician